基于运行PMSG的不同负荷工况下WECS的建模与分析

A. Gencer
{"title":"基于运行PMSG的不同负荷工况下WECS的建模与分析","authors":"A. Gencer","doi":"10.1109/ECAI.2016.7861198","DOIUrl":null,"url":null,"abstract":"The permanent magnet synchronous generator (PMSG) is widely used in wind power generation due to its high energy efficiency and controllability. Unbalance load conditions or different load conditions effects PMSG operation system. Furthermore, these conditions occur in problematic operation and distorted converter currents. The operation condition of the PMSG system to the effects of variation load is observed in this study and the performances of the PMSG based on wind energy conversion system (WECS) are analyzed. Simulation of the whole system using a 850-kW PMSG based on WECS system is built in the Matlab Simulink. The power flow efficiency of a PMSG is implemented to this study and control of the system for WECS. The proposed model is proven to verify under different operation conditions.","PeriodicalId":122809,"journal":{"name":"2016 8th International Conference on Electronics, Computers and Artificial Intelligence (ECAI)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Modelling and analysis of operation PMSG based WECS under different load conditions\",\"authors\":\"A. Gencer\",\"doi\":\"10.1109/ECAI.2016.7861198\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The permanent magnet synchronous generator (PMSG) is widely used in wind power generation due to its high energy efficiency and controllability. Unbalance load conditions or different load conditions effects PMSG operation system. Furthermore, these conditions occur in problematic operation and distorted converter currents. The operation condition of the PMSG system to the effects of variation load is observed in this study and the performances of the PMSG based on wind energy conversion system (WECS) are analyzed. Simulation of the whole system using a 850-kW PMSG based on WECS system is built in the Matlab Simulink. The power flow efficiency of a PMSG is implemented to this study and control of the system for WECS. The proposed model is proven to verify under different operation conditions.\",\"PeriodicalId\":122809,\"journal\":{\"name\":\"2016 8th International Conference on Electronics, Computers and Artificial Intelligence (ECAI)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 8th International Conference on Electronics, Computers and Artificial Intelligence (ECAI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECAI.2016.7861198\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 8th International Conference on Electronics, Computers and Artificial Intelligence (ECAI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECAI.2016.7861198","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

永磁同步发电机以其高能效和可控性在风力发电中得到广泛应用。负载不平衡或不同的负载条件对PMSG运行系统产生影响。此外,这些情况发生在有问题的操作和变形的变换器电流。研究了PMSG系统在变负荷影响下的运行情况,分析了基于风能转换系统(WECS)的PMSG的性能。在Matlab Simulink中建立了基于wcs系统的850 kw PMSG对整个系统的仿真。本文将PMSG的功率流效率应用于wcs系统的研究与控制。该模型在不同的运行条件下得到了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modelling and analysis of operation PMSG based WECS under different load conditions
The permanent magnet synchronous generator (PMSG) is widely used in wind power generation due to its high energy efficiency and controllability. Unbalance load conditions or different load conditions effects PMSG operation system. Furthermore, these conditions occur in problematic operation and distorted converter currents. The operation condition of the PMSG system to the effects of variation load is observed in this study and the performances of the PMSG based on wind energy conversion system (WECS) are analyzed. Simulation of the whole system using a 850-kW PMSG based on WECS system is built in the Matlab Simulink. The power flow efficiency of a PMSG is implemented to this study and control of the system for WECS. The proposed model is proven to verify under different operation conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信