用于开关电源的双向高压电流检测电路

Marzieh Ekhtiari, E. Bruun, M. Andersen, Zhe Zhang
{"title":"用于开关电源的双向高压电流检测电路","authors":"Marzieh Ekhtiari, E. Bruun, M. Andersen, Zhe Zhang","doi":"10.1109/ICECS.2014.7050064","DOIUrl":null,"url":null,"abstract":"In order to control a power supply using piezoelectric transformer, AC current in the transformer needs to be measured. Due to the control strategy it is necessary to measure amplitude, phase angle and zero crossing of this current. In some applications there is common ground between primary and secondary sides of the transformer which is internally implemented inside the transformer. Therefore, current must be measured from the high voltage line in the presence of high input switching voltage. This paper proposes a resistive current sensing circuit based on discrete components useful for input voltages on the order of 200 V. The bandwidth is at least 200 kHz to allow fundamental frequency detection of piezoelectric transformers in use.","PeriodicalId":133747,"journal":{"name":"2014 21st IEEE International Conference on Electronics, Circuits and Systems (ICECS)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Bi-directional high-side current sense circuit for switch mode power supplies\",\"authors\":\"Marzieh Ekhtiari, E. Bruun, M. Andersen, Zhe Zhang\",\"doi\":\"10.1109/ICECS.2014.7050064\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to control a power supply using piezoelectric transformer, AC current in the transformer needs to be measured. Due to the control strategy it is necessary to measure amplitude, phase angle and zero crossing of this current. In some applications there is common ground between primary and secondary sides of the transformer which is internally implemented inside the transformer. Therefore, current must be measured from the high voltage line in the presence of high input switching voltage. This paper proposes a resistive current sensing circuit based on discrete components useful for input voltages on the order of 200 V. The bandwidth is at least 200 kHz to allow fundamental frequency detection of piezoelectric transformers in use.\",\"PeriodicalId\":133747,\"journal\":{\"name\":\"2014 21st IEEE International Conference on Electronics, Circuits and Systems (ICECS)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 21st IEEE International Conference on Electronics, Circuits and Systems (ICECS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICECS.2014.7050064\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 21st IEEE International Conference on Electronics, Circuits and Systems (ICECS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECS.2014.7050064","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

为了控制使用压电变压器的电源,需要测量变压器中的交流电流。由于控制策略的需要,需要测量该电流的幅值、相位角和过零。在一些应用中,变压器的一次侧和二次侧之间有共地,这是在变压器内部实现的。因此,在存在高输入开关电压的情况下,必须从高压线测量电流。本文提出了一种基于离散元件的电阻式电流传感电路,适用于200v量级的输入电压。带宽至少为200khz,以允许使用中的压电变压器的基频检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Bi-directional high-side current sense circuit for switch mode power supplies
In order to control a power supply using piezoelectric transformer, AC current in the transformer needs to be measured. Due to the control strategy it is necessary to measure amplitude, phase angle and zero crossing of this current. In some applications there is common ground between primary and secondary sides of the transformer which is internally implemented inside the transformer. Therefore, current must be measured from the high voltage line in the presence of high input switching voltage. This paper proposes a resistive current sensing circuit based on discrete components useful for input voltages on the order of 200 V. The bandwidth is at least 200 kHz to allow fundamental frequency detection of piezoelectric transformers in use.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信