表面肌电信号-力关系的时间和频率参数

Achmamad Abdelouahad, Abdelali Belkhou, A. Jbari, L. Bellarbi
{"title":"表面肌电信号-力关系的时间和频率参数","authors":"Achmamad Abdelouahad, Abdelali Belkhou, A. Jbari, L. Bellarbi","doi":"10.1109/ICOA.2018.8370547","DOIUrl":null,"url":null,"abstract":"This paper shows that time and frequency domains may be used to evaluate force of skeletal muscle. The surface electromyography sEMG can be used to quantify force level of the muscle contraction. The main objective of this work is the study of the relationship between different features of sEMG signal and force level of contraction. The most popular time and frequency parameters extracted from sEMG signal are root mean square (RMS), mean absolute value (MAV), median frequency (MDF) and mean power frequency (MPF). The results of the experiment showed an increasing in time domain parameters values and a decreasing in frequency domain parameters values during four successive contractions significantly with the increasing in force level contraction. Furthermore, the sensitivity is calculated for each parameters. (RMS) and (MPF) have been selected as the best features to evaluate muscle force.","PeriodicalId":433166,"journal":{"name":"2018 4th International Conference on Optimization and Applications (ICOA)","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Time and frequency parameters of sEMG signal — Force relationship\",\"authors\":\"Achmamad Abdelouahad, Abdelali Belkhou, A. Jbari, L. Bellarbi\",\"doi\":\"10.1109/ICOA.2018.8370547\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper shows that time and frequency domains may be used to evaluate force of skeletal muscle. The surface electromyography sEMG can be used to quantify force level of the muscle contraction. The main objective of this work is the study of the relationship between different features of sEMG signal and force level of contraction. The most popular time and frequency parameters extracted from sEMG signal are root mean square (RMS), mean absolute value (MAV), median frequency (MDF) and mean power frequency (MPF). The results of the experiment showed an increasing in time domain parameters values and a decreasing in frequency domain parameters values during four successive contractions significantly with the increasing in force level contraction. Furthermore, the sensitivity is calculated for each parameters. (RMS) and (MPF) have been selected as the best features to evaluate muscle force.\",\"PeriodicalId\":433166,\"journal\":{\"name\":\"2018 4th International Conference on Optimization and Applications (ICOA)\",\"volume\":\"61 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 4th International Conference on Optimization and Applications (ICOA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICOA.2018.8370547\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 4th International Conference on Optimization and Applications (ICOA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICOA.2018.8370547","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

本文表明,时间域和频率域都可以用来评价骨骼肌的受力。肌表电图(sEMG)可以量化肌肉收缩的力度。本工作的主要目的是研究表面肌电信号的不同特征与收缩力水平之间的关系。从表面肌电信号中提取的最常用的时间和频率参数是均方根(RMS)、平均绝对值(MAV)、中位数频率(MDF)和平均工频(MPF)。实验结果表明,在连续4次收缩过程中,随着力级收缩的增大,时域参数值显著增大,频域参数值显著减小。此外,还计算了各参数的灵敏度。(RMS)和(MPF)被选为评估肌肉力量的最佳特征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Time and frequency parameters of sEMG signal — Force relationship
This paper shows that time and frequency domains may be used to evaluate force of skeletal muscle. The surface electromyography sEMG can be used to quantify force level of the muscle contraction. The main objective of this work is the study of the relationship between different features of sEMG signal and force level of contraction. The most popular time and frequency parameters extracted from sEMG signal are root mean square (RMS), mean absolute value (MAV), median frequency (MDF) and mean power frequency (MPF). The results of the experiment showed an increasing in time domain parameters values and a decreasing in frequency domain parameters values during four successive contractions significantly with the increasing in force level contraction. Furthermore, the sensitivity is calculated for each parameters. (RMS) and (MPF) have been selected as the best features to evaluate muscle force.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信