中压6脉冲CSR,具有新颖的并联有源电源滤波器连接

M. Hamad, M. Masoud, K. Ahmed, B. Williams
{"title":"中压6脉冲CSR,具有新颖的并联有源电源滤波器连接","authors":"M. Hamad, M. Masoud, K. Ahmed, B. Williams","doi":"10.1109/IECON.2013.6699488","DOIUrl":null,"url":null,"abstract":"The 6-pulse controlled ac/dc converter produces harmonics. The input current total harmonic distortion and the input power factor which is firing delay angle dependent are major drawbacks and a compensation technique is mandatory. This paper introduces a compensated 6-pulse current source controlled rectifier with a shunt active power filter, APF, and tapped WYE front-end transformer configuration. The shunt APF is controlled using a predictive current control. It is connected to taps on the front end transformer secondary forming a novel star auto-transformer connection where voltage matching is achieved without the need of a high frequency coupling transformer. Simulation results are presented for a medium voltage converter which is scaled to allow low-voltage experimental confirmation.","PeriodicalId":237327,"journal":{"name":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Medium voltage 6-pulse CSR with a novel shunt active power filter connection\",\"authors\":\"M. Hamad, M. Masoud, K. Ahmed, B. Williams\",\"doi\":\"10.1109/IECON.2013.6699488\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The 6-pulse controlled ac/dc converter produces harmonics. The input current total harmonic distortion and the input power factor which is firing delay angle dependent are major drawbacks and a compensation technique is mandatory. This paper introduces a compensated 6-pulse current source controlled rectifier with a shunt active power filter, APF, and tapped WYE front-end transformer configuration. The shunt APF is controlled using a predictive current control. It is connected to taps on the front end transformer secondary forming a novel star auto-transformer connection where voltage matching is achieved without the need of a high frequency coupling transformer. Simulation results are presented for a medium voltage converter which is scaled to allow low-voltage experimental confirmation.\",\"PeriodicalId\":237327,\"journal\":{\"name\":\"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.2013.6699488\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2013.6699488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

6脉冲控制的ac/dc变换器产生谐波。输入电流、总谐波畸变和与发射延时角有关的输入功率因数是主要缺点,必须采用补偿技术。本文介绍了一种带并联有源滤波器、有源滤波器和抽头WYE前端变压器的补偿型6脉冲电流源控制整流器。并联APF采用预测电流控制进行控制。它连接到前端变压器二次抽头上,形成一种新颖的星形自耦变压器连接,无需高频耦合变压器即可实现电压匹配。给出了一种中压变换器的仿真结果,该变换器经过缩放,可以进行低压实验验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Medium voltage 6-pulse CSR with a novel shunt active power filter connection
The 6-pulse controlled ac/dc converter produces harmonics. The input current total harmonic distortion and the input power factor which is firing delay angle dependent are major drawbacks and a compensation technique is mandatory. This paper introduces a compensated 6-pulse current source controlled rectifier with a shunt active power filter, APF, and tapped WYE front-end transformer configuration. The shunt APF is controlled using a predictive current control. It is connected to taps on the front end transformer secondary forming a novel star auto-transformer connection where voltage matching is achieved without the need of a high frequency coupling transformer. Simulation results are presented for a medium voltage converter which is scaled to allow low-voltage experimental confirmation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信