{"title":"一种基于50MHz QCM电子振荡器电路的DNA序列检测生物传感器","authors":"E. Bustabad, G. Garcia, L. Rodríguez-Pardo, J. Faria, H. Perrot, C. Gabrielli, B. Bucur, M. Lazerges, Doug Rose, C. Compère, A. Arnau","doi":"10.1109/ICSENS.2009.5398346","DOIUrl":null,"url":null,"abstract":"This work deals with the development of a high sensibility DNA biosensor based on a 50MHz Quartz Crystal Microbalance (QCM) Oscillator Electronic Circuit. The designed QCM oscillator sensor is able to detect the presence of complementary DNAs in a solution that match the sequence on a given strand in function of the changes in the output frequency of the oscillator. The design is adapted so that the Barkhausen condition is satisfied even when the quartz is immerged in liquid media. Also a comparative study of the developed 50MHz biosensor in front of a QCM oscillator with smaller frequency is carried out, with object of checking if the sensibility of the oscillator increases, allowing to detect smaller concentrations of the complementary DNA.","PeriodicalId":262591,"journal":{"name":"2009 IEEE Sensors","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"A biosensor for detection of DNA sequences based on a 50MHz QCM electronic oscillator circuit\",\"authors\":\"E. Bustabad, G. Garcia, L. Rodríguez-Pardo, J. Faria, H. Perrot, C. Gabrielli, B. Bucur, M. Lazerges, Doug Rose, C. Compère, A. Arnau\",\"doi\":\"10.1109/ICSENS.2009.5398346\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work deals with the development of a high sensibility DNA biosensor based on a 50MHz Quartz Crystal Microbalance (QCM) Oscillator Electronic Circuit. The designed QCM oscillator sensor is able to detect the presence of complementary DNAs in a solution that match the sequence on a given strand in function of the changes in the output frequency of the oscillator. The design is adapted so that the Barkhausen condition is satisfied even when the quartz is immerged in liquid media. Also a comparative study of the developed 50MHz biosensor in front of a QCM oscillator with smaller frequency is carried out, with object of checking if the sensibility of the oscillator increases, allowing to detect smaller concentrations of the complementary DNA.\",\"PeriodicalId\":262591,\"journal\":{\"name\":\"2009 IEEE Sensors\",\"volume\":\"57 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2009.5398346\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2009.5398346","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本工作涉及基于50MHz石英晶体微平衡振荡器电子电路的高灵敏度DNA生物传感器的开发。所设计的QCM振荡器传感器能够在振荡器输出频率变化的函数中检测到溶液中与给定链上序列匹配的互补dna的存在。该设计经过调整,即使石英浸没在液体介质中,也能满足巴克豪森条件。此外,还将开发的50MHz生物传感器与频率较小的QCM振荡器进行了比较研究,目的是检查振荡器的灵敏度是否增加,从而可以检测到较小浓度的互补DNA。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A biosensor for detection of DNA sequences based on a 50MHz QCM electronic oscillator circuit
This work deals with the development of a high sensibility DNA biosensor based on a 50MHz Quartz Crystal Microbalance (QCM) Oscillator Electronic Circuit. The designed QCM oscillator sensor is able to detect the presence of complementary DNAs in a solution that match the sequence on a given strand in function of the changes in the output frequency of the oscillator. The design is adapted so that the Barkhausen condition is satisfied even when the quartz is immerged in liquid media. Also a comparative study of the developed 50MHz biosensor in front of a QCM oscillator with smaller frequency is carried out, with object of checking if the sensibility of the oscillator increases, allowing to detect smaller concentrations of the complementary DNA.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信