{"title":"对低温电流比较器灵敏度的详细计算结果","authors":"M. Early, M. A. V. Dam","doi":"10.1109/CPEM.1998.699840","DOIUrl":null,"url":null,"abstract":"A detailed calculation of the sensitivity of a cryogenic current comparator (CCC) has been completed. The model accounts for the current distribution on the closed external shield and the overlapped shield around the windings. Additional refinements to the model lead to excellent agreement with sensitivity measurements for a range of CCC geometries.","PeriodicalId":239228,"journal":{"name":"1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Results from a detailed calculation of the sensitivity of a cryogenic current comparator\",\"authors\":\"M. Early, M. A. V. Dam\",\"doi\":\"10.1109/CPEM.1998.699840\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A detailed calculation of the sensitivity of a cryogenic current comparator (CCC) has been completed. The model accounts for the current distribution on the closed external shield and the overlapped shield around the windings. Additional refinements to the model lead to excellent agreement with sensitivity measurements for a range of CCC geometries.\",\"PeriodicalId\":239228,\"journal\":{\"name\":\"1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.1998.699840\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.1998.699840","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Results from a detailed calculation of the sensitivity of a cryogenic current comparator
A detailed calculation of the sensitivity of a cryogenic current comparator (CCC) has been completed. The model accounts for the current distribution on the closed external shield and the overlapped shield around the windings. Additional refinements to the model lead to excellent agreement with sensitivity measurements for a range of CCC geometries.