基于模拟学习和离体验证的可操纵导尿管力估计*

A. Sayadi, Hamid Reza Nourani, M. Jolaei, J. Dargahi, Amir Hooshiar
{"title":"基于模拟学习和离体验证的可操纵导尿管力估计*","authors":"A. Sayadi, Hamid Reza Nourani, M. Jolaei, J. Dargahi, Amir Hooshiar","doi":"10.1109/ismr48346.2021.9661549","DOIUrl":null,"url":null,"abstract":"Monitoring and control of the contact force at the tip of soft flexural robots is of high application need, e.g., the tip force on radiofrequency ablation (RFA) catheters. In this study, a real-time tip force estimation method based on image-based shape-sensing and learning-from-simulation is provided. To this end, a generalized image-based shape-sensing technique for flexural robots was developed using the Bezier spline interpolation method. Afterward, the deflection of a commercial catheter subjected to a series of tip forces was simulated using nonlinear finite element modeling. Next, two independent data-driven models, i.e., artificial neural network (ANN) and support vector regression (SVR), were trained with a dataset with the Bezier spline control points as the inputs and tip forces as the output. For validation, the trained models were used for real-time tip force estimation while the catheter was pressed against porcine atrial tissue. The test was performed using a universal testing machine that recorded the ground-truth contact force. The comparison showed that the ANN model had a mean-absolute-error of 0.0217±0.0191 N, while the SVR model exhibited a mean absolute error of 0.0178 ± 0.0121 N and a correlation coefficient of 0.991. Moreover, the proposed method showed a minimum computational refresh rate of 646 Hz (ANN) and 917 Hz (SVR) during the validation experiment. The performance of the proposed method was in compliance with the clinical requirements of RFA therapy.","PeriodicalId":405817,"journal":{"name":"2021 International Symposium on Medical Robotics (ISMR)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Force Estimation on Steerable Catheters through Learning-from-Simulation with ex-vivo Validation*\",\"authors\":\"A. Sayadi, Hamid Reza Nourani, M. Jolaei, J. Dargahi, Amir Hooshiar\",\"doi\":\"10.1109/ismr48346.2021.9661549\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Monitoring and control of the contact force at the tip of soft flexural robots is of high application need, e.g., the tip force on radiofrequency ablation (RFA) catheters. In this study, a real-time tip force estimation method based on image-based shape-sensing and learning-from-simulation is provided. To this end, a generalized image-based shape-sensing technique for flexural robots was developed using the Bezier spline interpolation method. Afterward, the deflection of a commercial catheter subjected to a series of tip forces was simulated using nonlinear finite element modeling. Next, two independent data-driven models, i.e., artificial neural network (ANN) and support vector regression (SVR), were trained with a dataset with the Bezier spline control points as the inputs and tip forces as the output. For validation, the trained models were used for real-time tip force estimation while the catheter was pressed against porcine atrial tissue. The test was performed using a universal testing machine that recorded the ground-truth contact force. The comparison showed that the ANN model had a mean-absolute-error of 0.0217±0.0191 N, while the SVR model exhibited a mean absolute error of 0.0178 ± 0.0121 N and a correlation coefficient of 0.991. Moreover, the proposed method showed a minimum computational refresh rate of 646 Hz (ANN) and 917 Hz (SVR) during the validation experiment. The performance of the proposed method was in compliance with the clinical requirements of RFA therapy.\",\"PeriodicalId\":405817,\"journal\":{\"name\":\"2021 International Symposium on Medical Robotics (ISMR)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Symposium on Medical Robotics (ISMR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ismr48346.2021.9661549\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Symposium on Medical Robotics (ISMR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ismr48346.2021.9661549","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

柔性机器人尖端接触力的监测和控制具有很高的应用需求,例如射频消融(RFA)导管的尖端力。本文提出了一种基于图像形状感知和模拟学习的实时尖端力估计方法。为此,采用贝塞尔样条插值方法,开发了一种基于图像的弯曲机器人广义形状感知技术。然后,利用非线性有限元模型模拟了商用导管在一系列尖端力作用下的挠曲。接下来,以贝塞尔样条控制点为输入,尖端力为输出的数据集,训练两个独立的数据驱动模型,即人工神经网络(ANN)和支持向量回归(SVR)。为了验证,当导管压在猪心房组织上时,将训练好的模型用于实时尖端力估计。测试是使用通用试验机进行的,该试验机记录了地面真实接触力。结果表明,人工神经网络模型的平均绝对误差为0.0217±0.0191 N,支持向量回归模型的平均绝对误差为0.0178±0.0121 N,相关系数为0.991。在验证实验中,该方法的最小计算刷新率分别为646 Hz (ANN)和917 Hz (SVR)。该方法的性能符合RFA治疗的临床要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Force Estimation on Steerable Catheters through Learning-from-Simulation with ex-vivo Validation*
Monitoring and control of the contact force at the tip of soft flexural robots is of high application need, e.g., the tip force on radiofrequency ablation (RFA) catheters. In this study, a real-time tip force estimation method based on image-based shape-sensing and learning-from-simulation is provided. To this end, a generalized image-based shape-sensing technique for flexural robots was developed using the Bezier spline interpolation method. Afterward, the deflection of a commercial catheter subjected to a series of tip forces was simulated using nonlinear finite element modeling. Next, two independent data-driven models, i.e., artificial neural network (ANN) and support vector regression (SVR), were trained with a dataset with the Bezier spline control points as the inputs and tip forces as the output. For validation, the trained models were used for real-time tip force estimation while the catheter was pressed against porcine atrial tissue. The test was performed using a universal testing machine that recorded the ground-truth contact force. The comparison showed that the ANN model had a mean-absolute-error of 0.0217±0.0191 N, while the SVR model exhibited a mean absolute error of 0.0178 ± 0.0121 N and a correlation coefficient of 0.991. Moreover, the proposed method showed a minimum computational refresh rate of 646 Hz (ANN) and 917 Hz (SVR) during the validation experiment. The performance of the proposed method was in compliance with the clinical requirements of RFA therapy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信