M. Bortolozzi, L. Branz, A. Tessarolo, C. Bruzzese
{"title":"一种计算半封闭槽内圆棒漏感的改进解析式","authors":"M. Bortolozzi, L. Branz, A. Tessarolo, C. Bruzzese","doi":"10.1109/SMART.2015.7399265","DOIUrl":null,"url":null,"abstract":"Round conductive bars embedded in semi-closed slots are frequently used in the construction of electric machinery, for instance in the squirrel cage of induction motors. Frequently, such as in the study of induction motor steady-state performance at rated slip, it is useful to estimate the slot leakage inductance of these conductors under the hypothesis of no eddy currents and no magnetic saturation. This is usually done through simple approximated analytical formulas available in the literature. In this paper, an improved explicit ready-to-use leakage inductance expression for circular bars embedded in semi-closed slots is derived by solving Poisson's equation in the slot domain. The precision of the proposed formulation is assessed against Finite Element Analysis (FEA) for various slot geometries and is shown to always give very accurate results, with errors below 2%. Conversely, approximated simplified formulas available from the literature are demonstrated to possibly give large errors, which exceed 20% for some explored slot geometries.","PeriodicalId":365573,"journal":{"name":"2015 International Conference on Sustainable Mobility Applications, Renewables and Technology (SMART)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"An improved analytical expression for computing the leakage inductance of a circular bar in a semi-closed slot\",\"authors\":\"M. Bortolozzi, L. Branz, A. Tessarolo, C. Bruzzese\",\"doi\":\"10.1109/SMART.2015.7399265\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Round conductive bars embedded in semi-closed slots are frequently used in the construction of electric machinery, for instance in the squirrel cage of induction motors. Frequently, such as in the study of induction motor steady-state performance at rated slip, it is useful to estimate the slot leakage inductance of these conductors under the hypothesis of no eddy currents and no magnetic saturation. This is usually done through simple approximated analytical formulas available in the literature. In this paper, an improved explicit ready-to-use leakage inductance expression for circular bars embedded in semi-closed slots is derived by solving Poisson's equation in the slot domain. The precision of the proposed formulation is assessed against Finite Element Analysis (FEA) for various slot geometries and is shown to always give very accurate results, with errors below 2%. Conversely, approximated simplified formulas available from the literature are demonstrated to possibly give large errors, which exceed 20% for some explored slot geometries.\",\"PeriodicalId\":365573,\"journal\":{\"name\":\"2015 International Conference on Sustainable Mobility Applications, Renewables and Technology (SMART)\",\"volume\":\"58 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Sustainable Mobility Applications, Renewables and Technology (SMART)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SMART.2015.7399265\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Sustainable Mobility Applications, Renewables and Technology (SMART)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SMART.2015.7399265","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An improved analytical expression for computing the leakage inductance of a circular bar in a semi-closed slot
Round conductive bars embedded in semi-closed slots are frequently used in the construction of electric machinery, for instance in the squirrel cage of induction motors. Frequently, such as in the study of induction motor steady-state performance at rated slip, it is useful to estimate the slot leakage inductance of these conductors under the hypothesis of no eddy currents and no magnetic saturation. This is usually done through simple approximated analytical formulas available in the literature. In this paper, an improved explicit ready-to-use leakage inductance expression for circular bars embedded in semi-closed slots is derived by solving Poisson's equation in the slot domain. The precision of the proposed formulation is assessed against Finite Element Analysis (FEA) for various slot geometries and is shown to always give very accurate results, with errors below 2%. Conversely, approximated simplified formulas available from the literature are demonstrated to possibly give large errors, which exceed 20% for some explored slot geometries.