矩阵变换器战场电源输出保护策略

B. Augdahl, H. Hess, B.K. Johnson, D. Katsis
{"title":"矩阵变换器战场电源输出保护策略","authors":"B. Augdahl, H. Hess, B.K. Johnson, D. Katsis","doi":"10.1109/NAPS.2005.1560517","DOIUrl":null,"url":null,"abstract":"The US Army Research Laboratory is currently studying the application of matrix converters to supply battlefield loads using variable speed diesel generators by utilizing a matrix converter to provide a bidirectional, three-phase to three-phase, direct AC to AC link between a diesel generator and load. This allows more efficient and economical operation of the diesel generators. A very brief overview of the matrix converter and standard protection strategies is presented, followed by new output protection strategies. The new output protection strategies account for the presence of the third harmonic component in the matrix converter output. Simulations are then presented to prove that the added output protection is capable of protecting a matrix converter and load when used in battlefield applications while adding increased selectivity and diagnostic capabilities.","PeriodicalId":101495,"journal":{"name":"Proceedings of the 37th Annual North American Power Symposium, 2005.","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Output protection strategies for battlefield power supplied by matrix converters\",\"authors\":\"B. Augdahl, H. Hess, B.K. Johnson, D. Katsis\",\"doi\":\"10.1109/NAPS.2005.1560517\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The US Army Research Laboratory is currently studying the application of matrix converters to supply battlefield loads using variable speed diesel generators by utilizing a matrix converter to provide a bidirectional, three-phase to three-phase, direct AC to AC link between a diesel generator and load. This allows more efficient and economical operation of the diesel generators. A very brief overview of the matrix converter and standard protection strategies is presented, followed by new output protection strategies. The new output protection strategies account for the presence of the third harmonic component in the matrix converter output. Simulations are then presented to prove that the added output protection is capable of protecting a matrix converter and load when used in battlefield applications while adding increased selectivity and diagnostic capabilities.\",\"PeriodicalId\":101495,\"journal\":{\"name\":\"Proceedings of the 37th Annual North American Power Symposium, 2005.\",\"volume\":\"114 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 37th Annual North American Power Symposium, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.2005.1560517\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 37th Annual North American Power Symposium, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2005.1560517","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

美国陆军研究实验室目前正在研究矩阵变换器的应用,通过利用矩阵变换器在柴油发电机和负载之间提供双向、三相到三相、直接交流到交流的连接,为使用变速柴油发电机的战场负载提供电源。这使得柴油发电机的运行更加高效和经济。简要介绍了矩阵变换器和标准保护策略,然后介绍了新的输出保护策略。新的输出保护策略考虑了矩阵变换器输出中存在的三次谐波分量。仿真结果表明,在战场应用中,增加的输出保护能够保护矩阵变换器和负载,同时增加了选择性和诊断能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Output protection strategies for battlefield power supplied by matrix converters
The US Army Research Laboratory is currently studying the application of matrix converters to supply battlefield loads using variable speed diesel generators by utilizing a matrix converter to provide a bidirectional, three-phase to three-phase, direct AC to AC link between a diesel generator and load. This allows more efficient and economical operation of the diesel generators. A very brief overview of the matrix converter and standard protection strategies is presented, followed by new output protection strategies. The new output protection strategies account for the presence of the third harmonic component in the matrix converter output. Simulations are then presented to prove that the added output protection is capable of protecting a matrix converter and load when used in battlefield applications while adding increased selectivity and diagnostic capabilities.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信