结合x射线和伽马射线测试研究倒装fpga的TID公差

N. Rezzak, Jih-Jong Wang, V. Nguyen, Durwyn Dsilva
{"title":"结合x射线和伽马射线测试研究倒装fpga的TID公差","authors":"N. Rezzak, Jih-Jong Wang, V. Nguyen, Durwyn Dsilva","doi":"10.1109/RADECS.2017.8696120","DOIUrl":null,"url":null,"abstract":"This paper investigates and proves the use of xray testing as a methodology and/or complement for TID testing of flip-chip FPGAs to identify the most sensitive circuit. This testing methodology can be used to test any flip-chip FPGA, Flash-based and SRAM-based. Microsemi’s RTG4 flip-chip FPGA is characterized with gamma ray to prove the concept and in addition do a detailed investigation of RTG4’s TID sensitive circuits. The advantage of using x-ray as a proxy for gamma-ray TID testing is that shielding can be used to identify the most sensitive circuits. In this paper both gamma-ray and x-ray results of RTG4 are presented and compared. Furthermore, during this investigation we discovered that the most important mechanism causing the failure of RTG4 re-programming is the degradation of the high voltage devices in the high voltage generation and word line access circuits.","PeriodicalId":223580,"journal":{"name":"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)","volume":"107 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Combined x-ray and gamma ray testing to investigate the TID tolerance of flip-chip FPGAs\",\"authors\":\"N. Rezzak, Jih-Jong Wang, V. Nguyen, Durwyn Dsilva\",\"doi\":\"10.1109/RADECS.2017.8696120\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates and proves the use of xray testing as a methodology and/or complement for TID testing of flip-chip FPGAs to identify the most sensitive circuit. This testing methodology can be used to test any flip-chip FPGA, Flash-based and SRAM-based. Microsemi’s RTG4 flip-chip FPGA is characterized with gamma ray to prove the concept and in addition do a detailed investigation of RTG4’s TID sensitive circuits. The advantage of using x-ray as a proxy for gamma-ray TID testing is that shielding can be used to identify the most sensitive circuits. In this paper both gamma-ray and x-ray results of RTG4 are presented and compared. Furthermore, during this investigation we discovered that the most important mechanism causing the failure of RTG4 re-programming is the degradation of the high voltage devices in the high voltage generation and word line access circuits.\",\"PeriodicalId\":223580,\"journal\":{\"name\":\"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)\",\"volume\":\"107 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RADECS.2017.8696120\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RADECS.2017.8696120","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文研究并证明了使用x射线测试作为倒装fpga TID测试的方法和/或补充,以识别最敏感的电路。该测试方法可用于测试任何基于FPGA、flash和sram的倒装芯片。Microsemi的RTG4倒装芯片FPGA以伽马射线为特征来证明这一概念,此外还对RTG4的TID敏感电路进行了详细的研究。使用x射线作为伽马射线TID测试代理的优点是屏蔽可以用来识别最敏感的电路。本文给出并比较了RTG4的伽玛射线和x射线结果。此外,在这项研究中,我们发现导致RTG4重编程失败的最重要机制是高压产生和字线接入电路中高压器件的退化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Combined x-ray and gamma ray testing to investigate the TID tolerance of flip-chip FPGAs
This paper investigates and proves the use of xray testing as a methodology and/or complement for TID testing of flip-chip FPGAs to identify the most sensitive circuit. This testing methodology can be used to test any flip-chip FPGA, Flash-based and SRAM-based. Microsemi’s RTG4 flip-chip FPGA is characterized with gamma ray to prove the concept and in addition do a detailed investigation of RTG4’s TID sensitive circuits. The advantage of using x-ray as a proxy for gamma-ray TID testing is that shielding can be used to identify the most sensitive circuits. In this paper both gamma-ray and x-ray results of RTG4 are presented and compared. Furthermore, during this investigation we discovered that the most important mechanism causing the failure of RTG4 re-programming is the degradation of the high voltage devices in the high voltage generation and word line access circuits.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信