最大限度地减少漏检和误报警的系统设计:电弧故障检测的案例研究

K. Fowler, H. B. Land
{"title":"最大限度地减少漏检和误报警的系统设计:电弧故障检测的案例研究","authors":"K. Fowler, H. B. Land","doi":"10.1109/IMTC.2004.1351531","DOIUrl":null,"url":null,"abstract":"This paper considers several components in the architecture and design of systems to discriminate conditions and fuse the data. It focuses on the problems of missing detections and reducing the possibility of generating false positive alarms. It uses a case study of a protective system that detects arcing faults in power switchboards on board ships. The results in this paper can be used in many systems that must monitor and detect hazardous events both accurately and consistently while minimizing false positive alarms that can cause harmful results. Examples include power plants, hospitals, computer installations, web servers, military sensors that detect enemy vehicles, aircraft engine monitoring, and telecommunications.","PeriodicalId":386903,"journal":{"name":"Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)","volume":"31 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"System design that minimizes both missed detections and false alarms: a case study in arc fault detection\",\"authors\":\"K. Fowler, H. B. Land\",\"doi\":\"10.1109/IMTC.2004.1351531\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper considers several components in the architecture and design of systems to discriminate conditions and fuse the data. It focuses on the problems of missing detections and reducing the possibility of generating false positive alarms. It uses a case study of a protective system that detects arcing faults in power switchboards on board ships. The results in this paper can be used in many systems that must monitor and detect hazardous events both accurately and consistently while minimizing false positive alarms that can cause harmful results. Examples include power plants, hospitals, computer installations, web servers, military sensors that detect enemy vehicles, aircraft engine monitoring, and telecommunications.\",\"PeriodicalId\":386903,\"journal\":{\"name\":\"Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)\",\"volume\":\"31 1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-05-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.2004.1351531\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2004.1351531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本文考虑了系统架构和设计中的几个组成部分来区分条件和融合数据。它侧重于遗漏检测和减少产生误报警报的可能性的问题。它使用了一个保护系统的案例研究,该系统可以检测船上电源配电盘中的电弧故障。本文的结果可用于许多必须准确和一致地监测和检测危险事件,同时最大限度地减少可能导致有害结果的误报警报的系统。例子包括发电厂、医院、计算机设施、web服务器、探测敌方车辆的军事传感器、飞机发动机监控和电信。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
System design that minimizes both missed detections and false alarms: a case study in arc fault detection
This paper considers several components in the architecture and design of systems to discriminate conditions and fuse the data. It focuses on the problems of missing detections and reducing the possibility of generating false positive alarms. It uses a case study of a protective system that detects arcing faults in power switchboards on board ships. The results in this paper can be used in many systems that must monitor and detect hazardous events both accurately and consistently while minimizing false positive alarms that can cause harmful results. Examples include power plants, hospitals, computer installations, web servers, military sensors that detect enemy vehicles, aircraft engine monitoring, and telecommunications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信