E. Aboadla, Sheroz Khan, M. H. Habaebi, T. Gunawan, B. A. Hamidah, Majdee Tohtayong
{"title":"基于选择性消谐波技术的调制优化对单相h桥逆变器总谐波畸变的影响","authors":"E. Aboadla, Sheroz Khan, M. H. Habaebi, T. Gunawan, B. A. Hamidah, Majdee Tohtayong","doi":"10.1109/ICCCE.2016.52","DOIUrl":null,"url":null,"abstract":"Specific odd harmonics can be mitigated by operating the simeconductor switches in H-bridge inverters at optimized switching angles of the PWM signals. These switching angles can be achieved by calculating a set of nonlinear equations using Selective Harmonic Elimination Pulse Width Modulation (SHE PWM) technique. Modulation index (m) is a significant parameter used to control the amplitude of the fundamental output voltage of DC-AC inverter. By changing the value of modulation index the Total Harmonics Distortion (THD) also will change. In this paper, the influence of varying modulation index on the THD, and the performance of H-bridge inverter using SHE PWM scheme is evaluated. To investigate the effect different conditions of modulation index and different number of nonlinear equations to calculate the switching angles to achieve a minimum THD, single phase H-bridge inverter is simulated in Matlab-Simulink.","PeriodicalId":360454,"journal":{"name":"2016 International Conference on Computer and Communication Engineering (ICCCE)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Modulation Optimization Effect on Total Harmonic Distortion of Single Phase H-Bridge Inverter Based Selective Harmonics Elimination Technique\",\"authors\":\"E. Aboadla, Sheroz Khan, M. H. Habaebi, T. Gunawan, B. A. Hamidah, Majdee Tohtayong\",\"doi\":\"10.1109/ICCCE.2016.52\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Specific odd harmonics can be mitigated by operating the simeconductor switches in H-bridge inverters at optimized switching angles of the PWM signals. These switching angles can be achieved by calculating a set of nonlinear equations using Selective Harmonic Elimination Pulse Width Modulation (SHE PWM) technique. Modulation index (m) is a significant parameter used to control the amplitude of the fundamental output voltage of DC-AC inverter. By changing the value of modulation index the Total Harmonics Distortion (THD) also will change. In this paper, the influence of varying modulation index on the THD, and the performance of H-bridge inverter using SHE PWM scheme is evaluated. To investigate the effect different conditions of modulation index and different number of nonlinear equations to calculate the switching angles to achieve a minimum THD, single phase H-bridge inverter is simulated in Matlab-Simulink.\",\"PeriodicalId\":360454,\"journal\":{\"name\":\"2016 International Conference on Computer and Communication Engineering (ICCCE)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 International Conference on Computer and Communication Engineering (ICCCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCCE.2016.52\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Computer and Communication Engineering (ICCCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCCE.2016.52","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Modulation Optimization Effect on Total Harmonic Distortion of Single Phase H-Bridge Inverter Based Selective Harmonics Elimination Technique
Specific odd harmonics can be mitigated by operating the simeconductor switches in H-bridge inverters at optimized switching angles of the PWM signals. These switching angles can be achieved by calculating a set of nonlinear equations using Selective Harmonic Elimination Pulse Width Modulation (SHE PWM) technique. Modulation index (m) is a significant parameter used to control the amplitude of the fundamental output voltage of DC-AC inverter. By changing the value of modulation index the Total Harmonics Distortion (THD) also will change. In this paper, the influence of varying modulation index on the THD, and the performance of H-bridge inverter using SHE PWM scheme is evaluated. To investigate the effect different conditions of modulation index and different number of nonlinear equations to calculate the switching angles to achieve a minimum THD, single phase H-bridge inverter is simulated in Matlab-Simulink.