{"title":"晶体光伏组件在casamance和cologne气候下暴露数年后的降解及对比实验研究","authors":"Issa Faye, Gabriel Jean Philippe, Ababacar Ndiaye, U. Blieske, D. Kobor, R. Gecke","doi":"10.1109/IESC.2018.8439990","DOIUrl":null,"url":null,"abstract":"In the present study, degradation analysis of two System of 20 poly-crystalline silicon PV module are investigated. This study reports data collected from 20 distinct poly-crystalline modules deployed at two cities with different weather conditions. The first system is installed in Casamance (Senegal), and the second one in Cologne (Germany). After a few years exposition in outdoor, a comprehensive analysis has been carried out through visual inspection, infrared thermal imaging and I-V characteristic. The global degradation of the power output (Pmax) has been measured to be from 8.75%/year to 22.45%/year in Casamance and 0.8%/year to 1,4%/year in Cologne. The following degradation mechanism have been detected: delamination (corrosion), hot-spot, soiling and cell crack.","PeriodicalId":147306,"journal":{"name":"2018 7th International Energy and Sustainability Conference (IESC)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Degradation and comparative experimental study of crystalline photovoltaic module after a few years outdoor exposure in casamance and cologne climate\",\"authors\":\"Issa Faye, Gabriel Jean Philippe, Ababacar Ndiaye, U. Blieske, D. Kobor, R. Gecke\",\"doi\":\"10.1109/IESC.2018.8439990\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the present study, degradation analysis of two System of 20 poly-crystalline silicon PV module are investigated. This study reports data collected from 20 distinct poly-crystalline modules deployed at two cities with different weather conditions. The first system is installed in Casamance (Senegal), and the second one in Cologne (Germany). After a few years exposition in outdoor, a comprehensive analysis has been carried out through visual inspection, infrared thermal imaging and I-V characteristic. The global degradation of the power output (Pmax) has been measured to be from 8.75%/year to 22.45%/year in Casamance and 0.8%/year to 1,4%/year in Cologne. The following degradation mechanism have been detected: delamination (corrosion), hot-spot, soiling and cell crack.\",\"PeriodicalId\":147306,\"journal\":{\"name\":\"2018 7th International Energy and Sustainability Conference (IESC)\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 7th International Energy and Sustainability Conference (IESC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IESC.2018.8439990\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 7th International Energy and Sustainability Conference (IESC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IESC.2018.8439990","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

在本研究中,研究了两种体系的20多晶硅光伏组件的降解分析。这项研究报告了从20个不同的多晶模块收集的数据,这些模块部署在两个不同天气条件的城市。第一个系统安装在卡萨芒斯(塞内加尔),第二个安装在科隆(德国)。经过几年的户外展览,通过目测、红外热成像和I-V特性对其进行了综合分析。在卡萨芒斯,功率输出(Pmax)的全球退化从8.75%/年到22.45%/年,在科隆从0.8%/年到1.4% /年。检测到以下降解机制:分层(腐蚀)、热点、污染和电池裂纹。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Degradation and comparative experimental study of crystalline photovoltaic module after a few years outdoor exposure in casamance and cologne climate
In the present study, degradation analysis of two System of 20 poly-crystalline silicon PV module are investigated. This study reports data collected from 20 distinct poly-crystalline modules deployed at two cities with different weather conditions. The first system is installed in Casamance (Senegal), and the second one in Cologne (Germany). After a few years exposition in outdoor, a comprehensive analysis has been carried out through visual inspection, infrared thermal imaging and I-V characteristic. The global degradation of the power output (Pmax) has been measured to be from 8.75%/year to 22.45%/year in Casamance and 0.8%/year to 1,4%/year in Cologne. The following degradation mechanism have been detected: delamination (corrosion), hot-spot, soiling and cell crack.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信