{"title":"低谐振频率LCL滤波器的无电网电压传感器控制","authors":"R. Fantino, C. Busada, J. Solsona","doi":"10.1109/PRIME-LA.2017.7899175","DOIUrl":null,"url":null,"abstract":"A Grid-Voltage sensorless control strategy for LCL Grid-connected voltage source inverters is proposed. Positive and negative grid sequences used for synchronization are estimated using an observer. The control of the system is implemented with a strategy that allows the use of the proportional plus resonant regulator (PR) optimum design, regardless of the filter resonance frequency. The effectiveness of the proposal is demonstrated by simulation in a realistic scenario.","PeriodicalId":163037,"journal":{"name":"2017 1st Conference on PhD Research in Microelectronics and Electronics Latin America (PRIME-LA)","volume":"128 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Grid-voltage sensorless control of an LCL filter with low resonance frequency\",\"authors\":\"R. Fantino, C. Busada, J. Solsona\",\"doi\":\"10.1109/PRIME-LA.2017.7899175\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A Grid-Voltage sensorless control strategy for LCL Grid-connected voltage source inverters is proposed. Positive and negative grid sequences used for synchronization are estimated using an observer. The control of the system is implemented with a strategy that allows the use of the proportional plus resonant regulator (PR) optimum design, regardless of the filter resonance frequency. The effectiveness of the proposal is demonstrated by simulation in a realistic scenario.\",\"PeriodicalId\":163037,\"journal\":{\"name\":\"2017 1st Conference on PhD Research in Microelectronics and Electronics Latin America (PRIME-LA)\",\"volume\":\"128 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 1st Conference on PhD Research in Microelectronics and Electronics Latin America (PRIME-LA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PRIME-LA.2017.7899175\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 1st Conference on PhD Research in Microelectronics and Electronics Latin America (PRIME-LA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PRIME-LA.2017.7899175","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Grid-voltage sensorless control of an LCL filter with low resonance frequency
A Grid-Voltage sensorless control strategy for LCL Grid-connected voltage source inverters is proposed. Positive and negative grid sequences used for synchronization are estimated using an observer. The control of the system is implemented with a strategy that allows the use of the proportional plus resonant regulator (PR) optimum design, regardless of the filter resonance frequency. The effectiveness of the proposal is demonstrated by simulation in a realistic scenario.