A. Valentino, A. Vera, C. Trujillo, A. Báez, H. Zepeda, L. Leija
{"title":"用反射系数法研究生物电磁吸收试验材料在200 MHz ~ 8.5 GHz频率范围内的相对介电率","authors":"A. Valentino, A. Vera, C. Trujillo, A. Báez, H. Zepeda, L. Leija","doi":"10.1109/ICEEE.2006.251905","DOIUrl":null,"url":null,"abstract":"This paper presents a study of the relative permittivity of different materials that are commonly used during electromagnetic absorption tests, e.g. hyperthermia and diathermia equipment characterization, specific absorption rate of cellular telephones, etc. The relative permittivity of materials is measured by using a probe based on the reflected wave and using a network analyzer. The materials tested were deionized water, used as reference, two muscle-like phantoms, and methacrylate, which is frequently used to make phantom containers. The permittivity values are presented in the frequency range from 200 MHz to 8.5 GHz","PeriodicalId":125310,"journal":{"name":"2006 3rd International Conference on Electrical and Electronics Engineering","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Relative Pemittivity Study of Materials Used in Biological Electromagnetic Absorption Tests by Using the Reflection Coefficient Method in the Frequency Range from 200 MHz to 8.5 GHz\",\"authors\":\"A. Valentino, A. Vera, C. Trujillo, A. Báez, H. Zepeda, L. Leija\",\"doi\":\"10.1109/ICEEE.2006.251905\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a study of the relative permittivity of different materials that are commonly used during electromagnetic absorption tests, e.g. hyperthermia and diathermia equipment characterization, specific absorption rate of cellular telephones, etc. The relative permittivity of materials is measured by using a probe based on the reflected wave and using a network analyzer. The materials tested were deionized water, used as reference, two muscle-like phantoms, and methacrylate, which is frequently used to make phantom containers. The permittivity values are presented in the frequency range from 200 MHz to 8.5 GHz\",\"PeriodicalId\":125310,\"journal\":{\"name\":\"2006 3rd International Conference on Electrical and Electronics Engineering\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 3rd International Conference on Electrical and Electronics Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEEE.2006.251905\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 3rd International Conference on Electrical and Electronics Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEEE.2006.251905","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Relative Pemittivity Study of Materials Used in Biological Electromagnetic Absorption Tests by Using the Reflection Coefficient Method in the Frequency Range from 200 MHz to 8.5 GHz
This paper presents a study of the relative permittivity of different materials that are commonly used during electromagnetic absorption tests, e.g. hyperthermia and diathermia equipment characterization, specific absorption rate of cellular telephones, etc. The relative permittivity of materials is measured by using a probe based on the reflected wave and using a network analyzer. The materials tested were deionized water, used as reference, two muscle-like phantoms, and methacrylate, which is frequently used to make phantom containers. The permittivity values are presented in the frequency range from 200 MHz to 8.5 GHz