{"title":"多机电力系统环境下欠激励限制器的整定","authors":"S. Choi, X. Jia","doi":"10.1109/PESW.2000.850070","DOIUrl":null,"url":null,"abstract":"Much interest on synchronous generator under-excitation limiters (UEL) has been devoted to the tuning of UEL in the single-machine-infinite-bus system. In this paper, the function of the UEL in a multi-machine power system is considered. Using a simplified model developed, some useful expressions pertaining to the UEL controller design have been derived. A tuning method which is based on the frequency response technique is proposed. The UEL control system will ensure that system stability is guaranteed.","PeriodicalId":286352,"journal":{"name":"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Tuning under-excitation limiters in the multi-machine power system environment\",\"authors\":\"S. Choi, X. Jia\",\"doi\":\"10.1109/PESW.2000.850070\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Much interest on synchronous generator under-excitation limiters (UEL) has been devoted to the tuning of UEL in the single-machine-infinite-bus system. In this paper, the function of the UEL in a multi-machine power system is considered. Using a simplified model developed, some useful expressions pertaining to the UEL controller design have been derived. A tuning method which is based on the frequency response technique is proposed. The UEL control system will ensure that system stability is guaranteed.\",\"PeriodicalId\":286352,\"journal\":{\"name\":\"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)\",\"volume\":\"56 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESW.2000.850070\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESW.2000.850070","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Tuning under-excitation limiters in the multi-machine power system environment
Much interest on synchronous generator under-excitation limiters (UEL) has been devoted to the tuning of UEL in the single-machine-infinite-bus system. In this paper, the function of the UEL in a multi-machine power system is considered. Using a simplified model developed, some useful expressions pertaining to the UEL controller design have been derived. A tuning method which is based on the frequency response technique is proposed. The UEL control system will ensure that system stability is guaranteed.