{"title":"电弧闪络引起的中压开关柜传导和辐射异常","authors":"K. Krause, D. Johnson","doi":"10.1109/PCICON.2012.6549651","DOIUrl":null,"url":null,"abstract":"Distribution networks are susceptible to spurious transients, both low and high frequency ringing, conducted and radiated emissions resulting from arc flash events. This paper introduces the phenomena of resonance and electromagnetic radiation emissions associated with the conductors and inherent capacitance. The paper addresses the effect on the peripheral equipment used for control and protection coordination as well as critical loads.","PeriodicalId":133636,"journal":{"name":"2012 Petroleum and Chemical Industry Conference (PCIC)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Conducted and radiated anomalies in medium voltage switchgear introduced by arc flash events\",\"authors\":\"K. Krause, D. Johnson\",\"doi\":\"10.1109/PCICON.2012.6549651\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Distribution networks are susceptible to spurious transients, both low and high frequency ringing, conducted and radiated emissions resulting from arc flash events. This paper introduces the phenomena of resonance and electromagnetic radiation emissions associated with the conductors and inherent capacitance. The paper addresses the effect on the peripheral equipment used for control and protection coordination as well as critical loads.\",\"PeriodicalId\":133636,\"journal\":{\"name\":\"2012 Petroleum and Chemical Industry Conference (PCIC)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Petroleum and Chemical Industry Conference (PCIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCICON.2012.6549651\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Petroleum and Chemical Industry Conference (PCIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCICON.2012.6549651","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Conducted and radiated anomalies in medium voltage switchgear introduced by arc flash events
Distribution networks are susceptible to spurious transients, both low and high frequency ringing, conducted and radiated emissions resulting from arc flash events. This paper introduces the phenomena of resonance and electromagnetic radiation emissions associated with the conductors and inherent capacitance. The paper addresses the effect on the peripheral equipment used for control and protection coordination as well as critical loads.