A. Yilmaz, Amirmahdi Sadeghimorad, I. Sahin, Z. Evren Kaya
{"title":"磁流变阻尼器控制半主动膝关节的性能分析","authors":"A. Yilmaz, Amirmahdi Sadeghimorad, I. Sahin, Z. Evren Kaya","doi":"10.1109/BIYOMUT.2014.7026338","DOIUrl":null,"url":null,"abstract":"Because of their short response time and ability to be controlled in real-time, use of MR dampers has been increased in the last decade in every area,. In prosthesis applications, it is important to maintain high levels of comfort and safety for the user. To achieve this objective stiffness of the damper utilized in prosthetics should be adjusted according to the gait phase and gait speed. In this study, to determine the necessary MR cylinder stiffness level, gait data of different users on different gait speeds were recorded. After determining the stiffness level of the prosthesis on different speeds, a Finite State Control algorithm was implemented for an above-knee proteshesis and the performance of this method was evaluated. Finally, performances of controlled and uncontrolled prostheses were compared to each other.","PeriodicalId":428610,"journal":{"name":"2014 18th National Biomedical Engineering Meeting","volume":"1119 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Analysis of the performance of controlled semi-active knee joint with magnetorheological (MR) damper\",\"authors\":\"A. Yilmaz, Amirmahdi Sadeghimorad, I. Sahin, Z. Evren Kaya\",\"doi\":\"10.1109/BIYOMUT.2014.7026338\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Because of their short response time and ability to be controlled in real-time, use of MR dampers has been increased in the last decade in every area,. In prosthesis applications, it is important to maintain high levels of comfort and safety for the user. To achieve this objective stiffness of the damper utilized in prosthetics should be adjusted according to the gait phase and gait speed. In this study, to determine the necessary MR cylinder stiffness level, gait data of different users on different gait speeds were recorded. After determining the stiffness level of the prosthesis on different speeds, a Finite State Control algorithm was implemented for an above-knee proteshesis and the performance of this method was evaluated. Finally, performances of controlled and uncontrolled prostheses were compared to each other.\",\"PeriodicalId\":428610,\"journal\":{\"name\":\"2014 18th National Biomedical Engineering Meeting\",\"volume\":\"1119 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 18th National Biomedical Engineering Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIYOMUT.2014.7026338\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 18th National Biomedical Engineering Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIYOMUT.2014.7026338","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of the performance of controlled semi-active knee joint with magnetorheological (MR) damper
Because of their short response time and ability to be controlled in real-time, use of MR dampers has been increased in the last decade in every area,. In prosthesis applications, it is important to maintain high levels of comfort and safety for the user. To achieve this objective stiffness of the damper utilized in prosthetics should be adjusted according to the gait phase and gait speed. In this study, to determine the necessary MR cylinder stiffness level, gait data of different users on different gait speeds were recorded. After determining the stiffness level of the prosthesis on different speeds, a Finite State Control algorithm was implemented for an above-knee proteshesis and the performance of this method was evaluated. Finally, performances of controlled and uncontrolled prostheses were compared to each other.