{"title":"薄膜纳米热电偶传感器在激光和电子束辐照中的应用","authors":"Dachen Chu, D. T. Bilir, R. F. Pease, K. Goodson","doi":"10.1109/SENSOR.2003.1216964","DOIUrl":null,"url":null,"abstract":"The continuous shrinking of transistors in VLSI circuits requires thermometry with high spatial, temporal and thermal resolution. Thin film thermocouple sensors have the potential to achieve small sensing volumes and junction areas. Gold/nickel thin film thermocouples with minimum junction size of (100 nm)/sup 2/ have been fabricated and characterized. While the smaller sensors improve spatial and temporal resolution, the data show reductions in the Seebeck coefficient (temperature sensitivity) and a larger influence of noise. These thin film thermocouples are used to determine the temperature profile of solid-state structures subjected to laser and electron beam irradiation.","PeriodicalId":196104,"journal":{"name":"TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Thin film nano thermocouple sensors for applications in laser and electron beam irradiation\",\"authors\":\"Dachen Chu, D. T. Bilir, R. F. Pease, K. Goodson\",\"doi\":\"10.1109/SENSOR.2003.1216964\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The continuous shrinking of transistors in VLSI circuits requires thermometry with high spatial, temporal and thermal resolution. Thin film thermocouple sensors have the potential to achieve small sensing volumes and junction areas. Gold/nickel thin film thermocouples with minimum junction size of (100 nm)/sup 2/ have been fabricated and characterized. While the smaller sensors improve spatial and temporal resolution, the data show reductions in the Seebeck coefficient (temperature sensitivity) and a larger influence of noise. These thin film thermocouples are used to determine the temperature profile of solid-state structures subjected to laser and electron beam irradiation.\",\"PeriodicalId\":196104,\"journal\":{\"name\":\"TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664)\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2003.1216964\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2003.1216964","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Thin film nano thermocouple sensors for applications in laser and electron beam irradiation
The continuous shrinking of transistors in VLSI circuits requires thermometry with high spatial, temporal and thermal resolution. Thin film thermocouple sensors have the potential to achieve small sensing volumes and junction areas. Gold/nickel thin film thermocouples with minimum junction size of (100 nm)/sup 2/ have been fabricated and characterized. While the smaller sensors improve spatial and temporal resolution, the data show reductions in the Seebeck coefficient (temperature sensitivity) and a larger influence of noise. These thin film thermocouples are used to determine the temperature profile of solid-state structures subjected to laser and electron beam irradiation.