具有M个冷备用单元的k -out- n系统的可靠性/可用性

Wendai Wang, J. Loman
{"title":"具有M个冷备用单元的k -out- n系统的可靠性/可用性","authors":"Wendai Wang, J. Loman","doi":"10.1109/RAMS.2002.981684","DOIUrl":null,"url":null,"abstract":"A generalized repairable system reliability model, K-out-of-N plus M cold standby units, is proposed in this paper. Reliability and availability of this system have been deeply studied under several combinations of assumptions/cases: identical and different cold standby, perfect and imperfect switching, and single backup and backup itself is a k-out-of-n system. Reliability evaluation of such systems is developed and provided. How to design this kind of power system to achieve its reliability requirements is studied and discussed. Factors that affect system reliability characteristics are presented. A real example of the defined system (on-site power plant) is provided through the developed approach. Reliability and availability of the power plant are evaluated, which is much-more reliable than the existing power sources. Further research and considerations are also discussed.","PeriodicalId":395613,"journal":{"name":"Annual Reliability and Maintainability Symposium. 2002 Proceedings (Cat. No.02CH37318)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":"{\"title\":\"Reliability/availability of K-out-of-N system with M cold standby units\",\"authors\":\"Wendai Wang, J. Loman\",\"doi\":\"10.1109/RAMS.2002.981684\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A generalized repairable system reliability model, K-out-of-N plus M cold standby units, is proposed in this paper. Reliability and availability of this system have been deeply studied under several combinations of assumptions/cases: identical and different cold standby, perfect and imperfect switching, and single backup and backup itself is a k-out-of-n system. Reliability evaluation of such systems is developed and provided. How to design this kind of power system to achieve its reliability requirements is studied and discussed. Factors that affect system reliability characteristics are presented. A real example of the defined system (on-site power plant) is provided through the developed approach. Reliability and availability of the power plant are evaluated, which is much-more reliable than the existing power sources. Further research and considerations are also discussed.\",\"PeriodicalId\":395613,\"journal\":{\"name\":\"Annual Reliability and Maintainability Symposium. 2002 Proceedings (Cat. No.02CH37318)\",\"volume\":\"77 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"23\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annual Reliability and Maintainability Symposium. 2002 Proceedings (Cat. No.02CH37318)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RAMS.2002.981684\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual Reliability and Maintainability Symposium. 2002 Proceedings (Cat. No.02CH37318)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RAMS.2002.981684","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

摘要

提出了一种广义的可修系统可靠性模型,即k -out- n + M冷备用单元。在相同和不同冷备、完全和不完全切换、单备份和备份本身是一个k- of-n系统的几种假设/情况组合下,对该系统的可靠性和可用性进行了深入研究。开发并提供了此类系统的可靠性评估。对如何设计这种电力系统以达到其可靠性要求进行了研究和探讨。给出了影响系统可靠性特性的因素。通过所开发的方法,给出了已定义系统(现场电厂)的实例。对该电站的可靠性和可用性进行了评估,结果表明该电站比现有的电源可靠得多。并讨论了进一步的研究和考虑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliability/availability of K-out-of-N system with M cold standby units
A generalized repairable system reliability model, K-out-of-N plus M cold standby units, is proposed in this paper. Reliability and availability of this system have been deeply studied under several combinations of assumptions/cases: identical and different cold standby, perfect and imperfect switching, and single backup and backup itself is a k-out-of-n system. Reliability evaluation of such systems is developed and provided. How to design this kind of power system to achieve its reliability requirements is studied and discussed. Factors that affect system reliability characteristics are presented. A real example of the defined system (on-site power plant) is provided through the developed approach. Reliability and availability of the power plant are evaluated, which is much-more reliable than the existing power sources. Further research and considerations are also discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信