{"title":"使用38 kHz和120 kHz测量Selar boops (Oxeye scad)的目标强度","authors":"Sunardi, A. Mohd, J. Din, R. Hassan, N. Seman","doi":"10.1109/APACE.2007.4603925","DOIUrl":null,"url":null,"abstract":"Furuno FQ-80 Scientific Echo Sounder can be performed on dual-frequency capabilities, 38 kHz and 120 kHz, as an individually or simultaneously. Measurement of target strength (TS) for Selar boops (Oxeye scad) had been deployed using FQ-80 on 228 dB and 236 dB of source level (SL) at low and high frequency, respectively. The fish were sited in the net cage at the bottom of the vessel. TS value, depth, and position (x-y-z) of single fish which detected at every ping at low and high frequency has been observed from recorded echogram using FQ-80 Analyzer. Fish TS detected at low and high frequency are ranging from -47.40 to -38.33 dB with the average of -44.49 dB and -45.19 to -42.76 dB with the average of -43.96 dB. Thus, fish TS detected at higher frequency is stronger than at lower frequency.","PeriodicalId":356424,"journal":{"name":"2007 Asia-Pacific Conference on Applied Electromagnetics","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Target strength measurement of Selar boops (Oxeye scad) using 38 kHz and 120 kHz\",\"authors\":\"Sunardi, A. Mohd, J. Din, R. Hassan, N. Seman\",\"doi\":\"10.1109/APACE.2007.4603925\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Furuno FQ-80 Scientific Echo Sounder can be performed on dual-frequency capabilities, 38 kHz and 120 kHz, as an individually or simultaneously. Measurement of target strength (TS) for Selar boops (Oxeye scad) had been deployed using FQ-80 on 228 dB and 236 dB of source level (SL) at low and high frequency, respectively. The fish were sited in the net cage at the bottom of the vessel. TS value, depth, and position (x-y-z) of single fish which detected at every ping at low and high frequency has been observed from recorded echogram using FQ-80 Analyzer. Fish TS detected at low and high frequency are ranging from -47.40 to -38.33 dB with the average of -44.49 dB and -45.19 to -42.76 dB with the average of -43.96 dB. Thus, fish TS detected at higher frequency is stronger than at lower frequency.\",\"PeriodicalId\":356424,\"journal\":{\"name\":\"2007 Asia-Pacific Conference on Applied Electromagnetics\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 Asia-Pacific Conference on Applied Electromagnetics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APACE.2007.4603925\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Asia-Pacific Conference on Applied Electromagnetics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APACE.2007.4603925","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Target strength measurement of Selar boops (Oxeye scad) using 38 kHz and 120 kHz
Furuno FQ-80 Scientific Echo Sounder can be performed on dual-frequency capabilities, 38 kHz and 120 kHz, as an individually or simultaneously. Measurement of target strength (TS) for Selar boops (Oxeye scad) had been deployed using FQ-80 on 228 dB and 236 dB of source level (SL) at low and high frequency, respectively. The fish were sited in the net cage at the bottom of the vessel. TS value, depth, and position (x-y-z) of single fish which detected at every ping at low and high frequency has been observed from recorded echogram using FQ-80 Analyzer. Fish TS detected at low and high frequency are ranging from -47.40 to -38.33 dB with the average of -44.49 dB and -45.19 to -42.76 dB with the average of -43.96 dB. Thus, fish TS detected at higher frequency is stronger than at lower frequency.