{"title":"i阴极的亮度和能量扩散测量","authors":"L. van Kouwen, M. van der Heijden, P. Kruit","doi":"10.1109/IVESC.2012.6264197","DOIUrl":null,"url":null,"abstract":"For possible use in a miniature scanning electron microscope, the brightness and energy spread of an impregnated cathode in triode configuration were measured. For a normalized brightness of 2.104 A/sr.m2.V we measured an energy spread of 0.8 e V.","PeriodicalId":249267,"journal":{"name":"IVESC 2012","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Brightness and energy spread measurements for an I-cathode\",\"authors\":\"L. van Kouwen, M. van der Heijden, P. Kruit\",\"doi\":\"10.1109/IVESC.2012.6264197\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For possible use in a miniature scanning electron microscope, the brightness and energy spread of an impregnated cathode in triode configuration were measured. For a normalized brightness of 2.104 A/sr.m2.V we measured an energy spread of 0.8 e V.\",\"PeriodicalId\":249267,\"journal\":{\"name\":\"IVESC 2012\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-04-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IVESC 2012\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IVESC.2012.6264197\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IVESC 2012","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IVESC.2012.6264197","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
为了可能在微型扫描电子显微镜中使用,测量了三极管结构中浸渍阴极的亮度和能量扩散。标准化亮度为2.104 a /sr.m2。我们测量到的能量扩散是0.8 ev。
Brightness and energy spread measurements for an I-cathode
For possible use in a miniature scanning electron microscope, the brightness and energy spread of an impregnated cathode in triode configuration were measured. For a normalized brightness of 2.104 A/sr.m2.V we measured an energy spread of 0.8 e V.