{"title":"三相δ电压不平衡的评定","authors":"N. Lopatkin","doi":"10.1109/MWENT47943.2020.9067480","DOIUrl":null,"url":null,"abstract":"Several existing three-phase delta voltages’ unbalance factors, including the \"true unbalance factor\" (the negative sequence voltage unbalance factor) and its complex form, are considered. New geometric criteria of delta voltages’ balance and unbalance, based on the dealing with delta voltages’ triangles of equal perimeters and different areas are offered. All the unbalance factors are shown in their dependences on one particular phase voltage (and also on one particular delta voltage), separately on the magnitude (for the case of a single-phase magnitude unbalance) and on the initial phase angle value (for the case of a single-phase angle unbalance). Also the fragment of a LabVIEW virtual instrument for the assessment of the negative sequence voltage unbalance factor and the new geometric factors is offered.","PeriodicalId":122716,"journal":{"name":"2020 Moscow Workshop on Electronic and Networking Technologies (MWENT)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"On the Assessment of Three-Phase Delta Voltages’ Unbalance\",\"authors\":\"N. Lopatkin\",\"doi\":\"10.1109/MWENT47943.2020.9067480\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Several existing three-phase delta voltages’ unbalance factors, including the \\\"true unbalance factor\\\" (the negative sequence voltage unbalance factor) and its complex form, are considered. New geometric criteria of delta voltages’ balance and unbalance, based on the dealing with delta voltages’ triangles of equal perimeters and different areas are offered. All the unbalance factors are shown in their dependences on one particular phase voltage (and also on one particular delta voltage), separately on the magnitude (for the case of a single-phase magnitude unbalance) and on the initial phase angle value (for the case of a single-phase angle unbalance). Also the fragment of a LabVIEW virtual instrument for the assessment of the negative sequence voltage unbalance factor and the new geometric factors is offered.\",\"PeriodicalId\":122716,\"journal\":{\"name\":\"2020 Moscow Workshop on Electronic and Networking Technologies (MWENT)\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 Moscow Workshop on Electronic and Networking Technologies (MWENT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MWENT47943.2020.9067480\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Moscow Workshop on Electronic and Networking Technologies (MWENT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWENT47943.2020.9067480","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
On the Assessment of Three-Phase Delta Voltages’ Unbalance
Several existing three-phase delta voltages’ unbalance factors, including the "true unbalance factor" (the negative sequence voltage unbalance factor) and its complex form, are considered. New geometric criteria of delta voltages’ balance and unbalance, based on the dealing with delta voltages’ triangles of equal perimeters and different areas are offered. All the unbalance factors are shown in their dependences on one particular phase voltage (and also on one particular delta voltage), separately on the magnitude (for the case of a single-phase magnitude unbalance) and on the initial phase angle value (for the case of a single-phase angle unbalance). Also the fragment of a LabVIEW virtual instrument for the assessment of the negative sequence voltage unbalance factor and the new geometric factors is offered.