{"title":"婴儿和婴儿人工呼吸装置的比较研究。","authors":"Z Rondio, M Rawicz","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In experiments on appropriately modified manikins the action and effectiveness of artificial respiration sets for infants Penlon (British production) and Ambu (Danish production) were compared. The tidal volume, pressure and characteristics of respiratory phases, rebreathing, oxygen concentration, safety systems and their effect on ventilation were assessed. It was found that better ventilation parameters for the needs of resuscitation of newborns and babies can be obtained using the Ambu set, particularly when compliance is lower and bronchial resistance is higher. The Ambu set is simple, easy and safe to use.</p>","PeriodicalId":75483,"journal":{"name":"Anaesthesia, resuscitation, and intensive therapy","volume":"4 4","pages":"273-9"},"PeriodicalIF":0.0000,"publicationDate":"1976-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative studies of artificial respiration sets for babies and infants.\",\"authors\":\"Z Rondio, M Rawicz\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In experiments on appropriately modified manikins the action and effectiveness of artificial respiration sets for infants Penlon (British production) and Ambu (Danish production) were compared. The tidal volume, pressure and characteristics of respiratory phases, rebreathing, oxygen concentration, safety systems and their effect on ventilation were assessed. It was found that better ventilation parameters for the needs of resuscitation of newborns and babies can be obtained using the Ambu set, particularly when compliance is lower and bronchial resistance is higher. The Ambu set is simple, easy and safe to use.</p>\",\"PeriodicalId\":75483,\"journal\":{\"name\":\"Anaesthesia, resuscitation, and intensive therapy\",\"volume\":\"4 4\",\"pages\":\"273-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1976-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anaesthesia, resuscitation, and intensive therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesia, resuscitation, and intensive therapy","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparative studies of artificial respiration sets for babies and infants.
In experiments on appropriately modified manikins the action and effectiveness of artificial respiration sets for infants Penlon (British production) and Ambu (Danish production) were compared. The tidal volume, pressure and characteristics of respiratory phases, rebreathing, oxygen concentration, safety systems and their effect on ventilation were assessed. It was found that better ventilation parameters for the needs of resuscitation of newborns and babies can be obtained using the Ambu set, particularly when compliance is lower and bronchial resistance is higher. The Ambu set is simple, easy and safe to use.