{"title":"直接光加工晶格结构的力学性能、压缩测试和单元格尺寸优化","authors":"Marinela Peto, E. Ramírez-Cedillo, M. J. Uddin, C. Rodríguez, H. Siller","doi":"10.1115/imece2019-12260","DOIUrl":null,"url":null,"abstract":"\n Lattice structures used for medical implants offer advantages related to weight reduction, osseointegration, and minimization of stress shielding. This paper intends to study and to compare the mechanical behavior of three different lattice structures: tetrahedral vertex centroid (TVC), hexagonal prism vertex centroid (HPVC), and cubic diamond (CD), that are designed to be incorporated in a shoulder hemiprosthesis. The unit cell configurations were generated using nTopology Element Pro software with a uniform strut thickness of 0.5 mm. Fifteen cuboid samples of 25mm × 25mm × 15 mm, five for each unit cell configuration, were additively manufactured using Direct Light Printing (DLP) technology with a layer height of 50μm and a XY resolution of 73μm. The mechanical behavior of the 3D printed lattice structures was examined by performing mechanical compression testing. E-silicone (methacrylated silicone) was used for the fabrication of samples, and its mechanical properties were obtained from experimental tensile testing of dog-bone samples. A methodology for size optimization of lattice unit cells is provided, and the optimization is achieved using nTopology Element Pro software. The generated results are analyzed, and the HPVC configuration is selected to be incorporated in the further design of prosthesis for bone cancer patients.","PeriodicalId":332737,"journal":{"name":"Volume 3: Biomedical and Biotechnology Engineering","volume":"64 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Mechanical Behavior of Lattice Structures Fabricated by Direct Light Processing With Compression Testing and Size Optimization of Unit Cells\",\"authors\":\"Marinela Peto, E. Ramírez-Cedillo, M. J. Uddin, C. Rodríguez, H. Siller\",\"doi\":\"10.1115/imece2019-12260\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Lattice structures used for medical implants offer advantages related to weight reduction, osseointegration, and minimization of stress shielding. This paper intends to study and to compare the mechanical behavior of three different lattice structures: tetrahedral vertex centroid (TVC), hexagonal prism vertex centroid (HPVC), and cubic diamond (CD), that are designed to be incorporated in a shoulder hemiprosthesis. The unit cell configurations were generated using nTopology Element Pro software with a uniform strut thickness of 0.5 mm. Fifteen cuboid samples of 25mm × 25mm × 15 mm, five for each unit cell configuration, were additively manufactured using Direct Light Printing (DLP) technology with a layer height of 50μm and a XY resolution of 73μm. The mechanical behavior of the 3D printed lattice structures was examined by performing mechanical compression testing. E-silicone (methacrylated silicone) was used for the fabrication of samples, and its mechanical properties were obtained from experimental tensile testing of dog-bone samples. A methodology for size optimization of lattice unit cells is provided, and the optimization is achieved using nTopology Element Pro software. The generated results are analyzed, and the HPVC configuration is selected to be incorporated in the further design of prosthesis for bone cancer patients.\",\"PeriodicalId\":332737,\"journal\":{\"name\":\"Volume 3: Biomedical and Biotechnology Engineering\",\"volume\":\"64 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 3: Biomedical and Biotechnology Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/imece2019-12260\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3: Biomedical and Biotechnology Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece2019-12260","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

用于医疗植入物的点阵结构具有减轻重量、骨整合和减少应力屏蔽的优点。本文研究并比较了三种不同晶格结构:四面体顶点质心(TVC)、六角形棱锥顶点质心(HPVC)和立方菱形(CD)的力学行为。使用nTopology Element Pro软件生成单元格配置,均匀支撑厚度为0.5 mm。采用直接光打印(Direct Light Printing, DLP)技术增材制造了15个25mm × 25mm × 15mm的长方体样品,每个单元格配置5个,层高50μm, XY分辨率73μm。通过机械压缩测试来检测3D打印晶格结构的力学性能。采用e -硅酮(甲基丙烯酸化硅酮)制备样品,并通过对狗骨样品的实验拉伸测试获得其力学性能。提供了一种晶格单元格尺寸优化的方法,并使用nTopology Element Pro软件实现了优化。对生成的结果进行分析,并选择HPVC结构纳入骨癌患者假体的进一步设计中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Mechanical Behavior of Lattice Structures Fabricated by Direct Light Processing With Compression Testing and Size Optimization of Unit Cells
Lattice structures used for medical implants offer advantages related to weight reduction, osseointegration, and minimization of stress shielding. This paper intends to study and to compare the mechanical behavior of three different lattice structures: tetrahedral vertex centroid (TVC), hexagonal prism vertex centroid (HPVC), and cubic diamond (CD), that are designed to be incorporated in a shoulder hemiprosthesis. The unit cell configurations were generated using nTopology Element Pro software with a uniform strut thickness of 0.5 mm. Fifteen cuboid samples of 25mm × 25mm × 15 mm, five for each unit cell configuration, were additively manufactured using Direct Light Printing (DLP) technology with a layer height of 50μm and a XY resolution of 73μm. The mechanical behavior of the 3D printed lattice structures was examined by performing mechanical compression testing. E-silicone (methacrylated silicone) was used for the fabrication of samples, and its mechanical properties were obtained from experimental tensile testing of dog-bone samples. A methodology for size optimization of lattice unit cells is provided, and the optimization is achieved using nTopology Element Pro software. The generated results are analyzed, and the HPVC configuration is selected to be incorporated in the further design of prosthesis for bone cancer patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信