发电机定子绕组不同工艺高压绝缘系统介电特性比较分析

K. K. Kumar, K. M. Reddy, P.G.S. Kumar
{"title":"发电机定子绕组不同工艺高压绝缘系统介电特性比较分析","authors":"K. K. Kumar, K. M. Reddy, P.G.S. Kumar","doi":"10.1109/ICHVET.2019.8724283","DOIUrl":null,"url":null,"abstract":"In the year 2018, two turbo generators (TG) of 150 MVA, 11KV rating at different power plants were tested for condition assessment by the authors. TG1 was at a base load power plant and completed 25 years of service. TG2 was at combined cycle power plant and served for 15 years. Based on the year of installation, it was established that high voltage insulation system of stator winding in TG1 was processed with resin rich (RR) thermo set technology and that in TG2 was processed with global vacuum pressure impregnation (GVPI), an advanced technology. In this paper, comparative finding on RR and GVPI technologies for insulation of stator winding in these two TGs was presented for familiarization. Condition assessment tests such as insulation resistance (IR), dielectric loss factor (tan δ), partial discharge (PD), natural frequency test (NFT) and slot wedge tightness (WTD) had been carried to detect the defects in insulation. Analysis of the test data was presented to interpret the dielectric behavior of these two variants. It was concluded that the dielectric parameters of insulation systems in both TGs were at satisfactory levels due to timely corrective actions on TG1 stator winding and due to GVPI processed insulation on TG2 stator winding.","PeriodicalId":165193,"journal":{"name":"2019 International Conference on High Voltage Engineering and Technology (ICHVET)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Analysis of Dielectric Characteristics of Differently Manufactured High Voltage Insulation System for Generator Stator Winding\",\"authors\":\"K. K. Kumar, K. M. Reddy, P.G.S. Kumar\",\"doi\":\"10.1109/ICHVET.2019.8724283\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the year 2018, two turbo generators (TG) of 150 MVA, 11KV rating at different power plants were tested for condition assessment by the authors. TG1 was at a base load power plant and completed 25 years of service. TG2 was at combined cycle power plant and served for 15 years. Based on the year of installation, it was established that high voltage insulation system of stator winding in TG1 was processed with resin rich (RR) thermo set technology and that in TG2 was processed with global vacuum pressure impregnation (GVPI), an advanced technology. In this paper, comparative finding on RR and GVPI technologies for insulation of stator winding in these two TGs was presented for familiarization. Condition assessment tests such as insulation resistance (IR), dielectric loss factor (tan δ), partial discharge (PD), natural frequency test (NFT) and slot wedge tightness (WTD) had been carried to detect the defects in insulation. Analysis of the test data was presented to interpret the dielectric behavior of these two variants. It was concluded that the dielectric parameters of insulation systems in both TGs were at satisfactory levels due to timely corrective actions on TG1 stator winding and due to GVPI processed insulation on TG2 stator winding.\",\"PeriodicalId\":165193,\"journal\":{\"name\":\"2019 International Conference on High Voltage Engineering and Technology (ICHVET)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on High Voltage Engineering and Technology (ICHVET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVET.2019.8724283\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on High Voltage Engineering and Technology (ICHVET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVET.2019.8724283","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

2018年,作者在不同的发电厂测试了两台150 MVA, 11KV额定的汽轮发电机(TG)进行状态评估。TG1是一个基本负荷发电厂,完成了25年的服务。TG2为联合循环电厂,已运行15年。根据安装年份,确定了TG1定子绕组高压绝缘系统采用富树脂(RR)热固性工艺,TG2定子绕组高压绝缘系统采用先进的全真空压力浸渍(GVPI)工艺。本文对这两种TGs定子绕组绝缘的RR和GVPI技术进行了对比研究,以供大家熟悉。通过绝缘电阻(IR)、介质损耗因子(tan δ)、局部放电(PD)、固有频率测试(NFT)和槽楔密封性(WTD)等状态评估试验来检测绝缘缺陷。通过对试验数据的分析,解释了这两种变体的介电性能。结果表明,由于对TG1定子绕组采取了及时的纠正措施,以及对TG2定子绕组进行了GVPI处理,两个tg的绝缘系统的介电参数都达到了满意的水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative Analysis of Dielectric Characteristics of Differently Manufactured High Voltage Insulation System for Generator Stator Winding
In the year 2018, two turbo generators (TG) of 150 MVA, 11KV rating at different power plants were tested for condition assessment by the authors. TG1 was at a base load power plant and completed 25 years of service. TG2 was at combined cycle power plant and served for 15 years. Based on the year of installation, it was established that high voltage insulation system of stator winding in TG1 was processed with resin rich (RR) thermo set technology and that in TG2 was processed with global vacuum pressure impregnation (GVPI), an advanced technology. In this paper, comparative finding on RR and GVPI technologies for insulation of stator winding in these two TGs was presented for familiarization. Condition assessment tests such as insulation resistance (IR), dielectric loss factor (tan δ), partial discharge (PD), natural frequency test (NFT) and slot wedge tightness (WTD) had been carried to detect the defects in insulation. Analysis of the test data was presented to interpret the dielectric behavior of these two variants. It was concluded that the dielectric parameters of insulation systems in both TGs were at satisfactory levels due to timely corrective actions on TG1 stator winding and due to GVPI processed insulation on TG2 stator winding.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信