{"title":"HDL垂直极化连续波仪器系统校准","authors":"J. Brackett, Y. Rosenberg, D. McDonald","doi":"10.1109/ISEMC.1991.148273","DOIUrl":null,"url":null,"abstract":"The HDL CW instrumentation system (CWIS) was developed to investigate electromagnetic pulse (EMP) coupling effects to transportable systems. The CWIS was fully calibrated by performing field mapping measurements, in both horizontal and vertical polarizations, of two test volumes. The vertical polarization calibration of the system is emphasized. A brief overview of the system is provided. Field mapping data is presented and analyzed. Measurements on simple electromagnetic shapes are presented and compared to theoretical computations.<<ETX>>","PeriodicalId":243730,"journal":{"name":"IEEE 1991 International Symposium on Electromagnetic Compatibility","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"HDL vertically polarized CW instrumentation system calibration\",\"authors\":\"J. Brackett, Y. Rosenberg, D. McDonald\",\"doi\":\"10.1109/ISEMC.1991.148273\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The HDL CW instrumentation system (CWIS) was developed to investigate electromagnetic pulse (EMP) coupling effects to transportable systems. The CWIS was fully calibrated by performing field mapping measurements, in both horizontal and vertical polarizations, of two test volumes. The vertical polarization calibration of the system is emphasized. A brief overview of the system is provided. Field mapping data is presented and analyzed. Measurements on simple electromagnetic shapes are presented and compared to theoretical computations.<<ETX>>\",\"PeriodicalId\":243730,\"journal\":{\"name\":\"IEEE 1991 International Symposium on Electromagnetic Compatibility\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE 1991 International Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.1991.148273\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 1991 International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1991.148273","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
HDL vertically polarized CW instrumentation system calibration
The HDL CW instrumentation system (CWIS) was developed to investigate electromagnetic pulse (EMP) coupling effects to transportable systems. The CWIS was fully calibrated by performing field mapping measurements, in both horizontal and vertical polarizations, of two test volumes. The vertical polarization calibration of the system is emphasized. A brief overview of the system is provided. Field mapping data is presented and analyzed. Measurements on simple electromagnetic shapes are presented and compared to theoretical computations.<>