A. Andang, Tri Cahyo Adi Pamungkas, N. Busaeri, R. S. Hartati, Ida B. G. Manuaba, I. Kumara
{"title":"采用FCS MPC的三相四腿逆变LC滤波器","authors":"A. Andang, Tri Cahyo Adi Pamungkas, N. Busaeri, R. S. Hartati, Ida B. G. Manuaba, I. Kumara","doi":"10.1109/ICSGTEIS53426.2021.9650376","DOIUrl":null,"url":null,"abstract":"The need to convert electric power from dc to ac is due to the growing development of renewable energy generation connected to an electric power distribution system. The power conversion is carried out with power inverters where a three-phase four-leg inverter, apart from being an electric power converter, turns out to stabilize the output voltage supplied to the load. The voltage on the distribution network can experience imbalance due to connection with an unbalanced three-phase load. This article presents a four-leg three-phase inverter using an LC filter using an MPC control to produce a sinusoidal output voltage and balance the voltage. From the simulation results, it is obtained that when the load is balanced, the THD of the output voltage is 0.3% - 0.5%, while in unbalanced load conditions, the THD of the output voltage is 0.2% - 1.7%, with a percentage of voltage imbalance of 0.1% - 0.9%.","PeriodicalId":345626,"journal":{"name":"2021 International Conference on Smart-Green Technology in Electrical and Information Systems (ICSGTEIS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Three-phase Four-leg Inverter LC Filter Using FCS MPC\",\"authors\":\"A. Andang, Tri Cahyo Adi Pamungkas, N. Busaeri, R. S. Hartati, Ida B. G. Manuaba, I. Kumara\",\"doi\":\"10.1109/ICSGTEIS53426.2021.9650376\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The need to convert electric power from dc to ac is due to the growing development of renewable energy generation connected to an electric power distribution system. The power conversion is carried out with power inverters where a three-phase four-leg inverter, apart from being an electric power converter, turns out to stabilize the output voltage supplied to the load. The voltage on the distribution network can experience imbalance due to connection with an unbalanced three-phase load. This article presents a four-leg three-phase inverter using an LC filter using an MPC control to produce a sinusoidal output voltage and balance the voltage. From the simulation results, it is obtained that when the load is balanced, the THD of the output voltage is 0.3% - 0.5%, while in unbalanced load conditions, the THD of the output voltage is 0.2% - 1.7%, with a percentage of voltage imbalance of 0.1% - 0.9%.\",\"PeriodicalId\":345626,\"journal\":{\"name\":\"2021 International Conference on Smart-Green Technology in Electrical and Information Systems (ICSGTEIS)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Smart-Green Technology in Electrical and Information Systems (ICSGTEIS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSGTEIS53426.2021.9650376\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Smart-Green Technology in Electrical and Information Systems (ICSGTEIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSGTEIS53426.2021.9650376","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Three-phase Four-leg Inverter LC Filter Using FCS MPC
The need to convert electric power from dc to ac is due to the growing development of renewable energy generation connected to an electric power distribution system. The power conversion is carried out with power inverters where a three-phase four-leg inverter, apart from being an electric power converter, turns out to stabilize the output voltage supplied to the load. The voltage on the distribution network can experience imbalance due to connection with an unbalanced three-phase load. This article presents a four-leg three-phase inverter using an LC filter using an MPC control to produce a sinusoidal output voltage and balance the voltage. From the simulation results, it is obtained that when the load is balanced, the THD of the output voltage is 0.3% - 0.5%, while in unbalanced load conditions, the THD of the output voltage is 0.2% - 1.7%, with a percentage of voltage imbalance of 0.1% - 0.9%.