一种改进的稳态视觉诱发电位脑机接口相标记刺激生成方法

C. Wong, Boyu Wang, F. Wan, P. Mak, Pu Mak, M. Vai
{"title":"一种改进的稳态视觉诱发电位脑机接口相标记刺激生成方法","authors":"C. Wong, Boyu Wang, F. Wan, P. Mak, Pu Mak, M. Vai","doi":"10.1109/BMEI.2010.5640083","DOIUrl":null,"url":null,"abstract":"This paper proposes an improved method for generating different phases of visual stimulus while liquid crystal display (LCD)/cathode ray tube (CRT) is employed as the visual stimulator. Since using the traditional method can only generate the limited frequencies and phases of visual stimulus, increasing the number of different flickering targets becomes very difficult in steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI). The experimental result shows that the proposed method can generate the visual stimulus with more phase angles than the traditional method. In addition, the proposed LCD visual stimulator can evoke the subject's SSVEP with expected phase.","PeriodicalId":231601,"journal":{"name":"2010 3rd International Conference on Biomedical Engineering and Informatics","volume":"254 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"An improved phase-tagged stimuli generation method in steady-state visual evoked potential based brain-computer interface\",\"authors\":\"C. Wong, Boyu Wang, F. Wan, P. Mak, Pu Mak, M. Vai\",\"doi\":\"10.1109/BMEI.2010.5640083\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes an improved method for generating different phases of visual stimulus while liquid crystal display (LCD)/cathode ray tube (CRT) is employed as the visual stimulator. Since using the traditional method can only generate the limited frequencies and phases of visual stimulus, increasing the number of different flickering targets becomes very difficult in steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI). The experimental result shows that the proposed method can generate the visual stimulus with more phase angles than the traditional method. In addition, the proposed LCD visual stimulator can evoke the subject's SSVEP with expected phase.\",\"PeriodicalId\":231601,\"journal\":{\"name\":\"2010 3rd International Conference on Biomedical Engineering and Informatics\",\"volume\":\"254 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 3rd International Conference on Biomedical Engineering and Informatics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BMEI.2010.5640083\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 3rd International Conference on Biomedical Engineering and Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BMEI.2010.5640083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

提出了一种利用液晶显示器(LCD)/阴极射线管(CRT)作为视觉刺激器产生不同相位视觉刺激的改进方法。由于传统方法只能产生有限频率和相位的视觉刺激,在基于稳态视觉诱发电位(SSVEP)的脑机接口(BCI)中,增加不同闪烁目标的数量变得非常困难。实验结果表明,与传统方法相比,该方法能产生更多相位角的视觉刺激。此外,所提出的LCD视觉刺激器能以预期的相位唤起被试的SSVEP。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An improved phase-tagged stimuli generation method in steady-state visual evoked potential based brain-computer interface
This paper proposes an improved method for generating different phases of visual stimulus while liquid crystal display (LCD)/cathode ray tube (CRT) is employed as the visual stimulator. Since using the traditional method can only generate the limited frequencies and phases of visual stimulus, increasing the number of different flickering targets becomes very difficult in steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI). The experimental result shows that the proposed method can generate the visual stimulus with more phase angles than the traditional method. In addition, the proposed LCD visual stimulator can evoke the subject's SSVEP with expected phase.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信