{"title":"未来强子量热计用表面安装sipm读出闪烁体瓦片的设计","authors":"Yong Liu, V. Buscher, J. Caudron, P. Chau, S. Krause, L. Masetti, U. Schafer, R. Spreckels, S. Tapprogge, R. Wanke","doi":"10.1109/NSSMIC.2014.7431118","DOIUrl":null,"url":null,"abstract":"Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten million channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough room for the whole SiPM package and to improve collection of the light produced by incident particles penetrating the tile at different positions. The cavity design has been optimized using a GEANT4-based full simulation model to achieve a high response to a Minimum Ionizing Particles (MIP) and also good spatial uniformity. The single-MIP response for scintillator tiles with an optimized cavity design has been measured using cosmic rays, which shows that a SiPM with a sensitive area of only 1 × 1 mm2 (Hamamatsu MPPC S12571-025P) reaches a mean response of more than 23 photon equivalents with a dynamic range of many tens of MIPs. A recent uniformity measurement for the same tile design is performed by scanning the tile area using focused electrons from a 90Sr source, which shows that around 97% (80%) of the tile area is within 90% (95%) response uniformity. This optimized design is well beyond the requirements for a precision hadron calorimeter.","PeriodicalId":144711,"journal":{"name":"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"137 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":"{\"title\":\"A design of scintillator tiles read out by surface-mounted SiPMs for a future hadron calorimeter\",\"authors\":\"Yong Liu, V. Buscher, J. Caudron, P. Chau, S. Krause, L. Masetti, U. Schafer, R. Spreckels, S. Tapprogge, R. Wanke\",\"doi\":\"10.1109/NSSMIC.2014.7431118\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten million channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough room for the whole SiPM package and to improve collection of the light produced by incident particles penetrating the tile at different positions. The cavity design has been optimized using a GEANT4-based full simulation model to achieve a high response to a Minimum Ionizing Particles (MIP) and also good spatial uniformity. The single-MIP response for scintillator tiles with an optimized cavity design has been measured using cosmic rays, which shows that a SiPM with a sensitive area of only 1 × 1 mm2 (Hamamatsu MPPC S12571-025P) reaches a mean response of more than 23 photon equivalents with a dynamic range of many tens of MIPs. A recent uniformity measurement for the same tile design is performed by scanning the tile area using focused electrons from a 90Sr source, which shows that around 97% (80%) of the tile area is within 90% (95%) response uniformity. This optimized design is well beyond the requirements for a precision hadron calorimeter.\",\"PeriodicalId\":144711,\"journal\":{\"name\":\"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"volume\":\"137 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"26\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2014.7431118\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2014.7431118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

摘要

基于CALICE合作的颗粒流概念,正在开发使用高颗粒取样量热计的精密量热法。强子量热计的一种设计选择是基于硅光电倍增管(SiPMs)来探测在塑料闪烁体瓦片中产生的光子。在高粒度要求的大约1000万个通道的自动化大规模组装需求的驱动下,我们开发了一种直接耦合表面贴装sipm的闪烁体瓦设计。在每个瓷砖底部表面的中心创建一个空腔,为整个SiPM包提供足够的空间,并改善入射粒子在不同位置穿透瓷砖产生的光的收集。利用基于geant4的全仿真模型对腔体设计进行了优化,实现了对最小电离粒子(MIP)的高响应和良好的空间均匀性。利用宇宙射线测量了具有优化腔体设计的闪烁体瓦的单mip响应,结果表明,敏感面积仅为1 × 1 mm2的SiPM (Hamamatsu MPPC S12571-025P)达到了超过23个光子当量的平均响应,动态范围为数十个mip。最近对相同的瓷砖设计进行了均匀性测量,使用来自90Sr源的聚焦电子扫描瓷砖区域,结果表明,大约97%(80%)的瓷砖区域在90%(95%)的响应均匀性范围内。这种优化设计远远超出了精密强子量热计的要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A design of scintillator tiles read out by surface-mounted SiPMs for a future hadron calorimeter
Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten million channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough room for the whole SiPM package and to improve collection of the light produced by incident particles penetrating the tile at different positions. The cavity design has been optimized using a GEANT4-based full simulation model to achieve a high response to a Minimum Ionizing Particles (MIP) and also good spatial uniformity. The single-MIP response for scintillator tiles with an optimized cavity design has been measured using cosmic rays, which shows that a SiPM with a sensitive area of only 1 × 1 mm2 (Hamamatsu MPPC S12571-025P) reaches a mean response of more than 23 photon equivalents with a dynamic range of many tens of MIPs. A recent uniformity measurement for the same tile design is performed by scanning the tile area using focused electrons from a 90Sr source, which shows that around 97% (80%) of the tile area is within 90% (95%) response uniformity. This optimized design is well beyond the requirements for a precision hadron calorimeter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信