参考箱,以控制测量低频HIRF传递函数

W. Quenum, I. Junqua, J. Parmantier, O. Verstraete, D. Lemaire, F. Therond
{"title":"参考箱,以控制测量低频HIRF传递函数","authors":"W. Quenum, I. Junqua, J. Parmantier, O. Verstraete, D. Lemaire, F. Therond","doi":"10.1109/APEMC.2015.7175372","DOIUrl":null,"url":null,"abstract":"This paper addresses the issue of transfer function measurements inside a structure in High Intensity Radiated Fields environment (HIRF). In this context, a simple reference test object was designed and used as a set up verification device to be tested before HIRF measurement campaigns on aircraft. In order to obtain a reference measured transfer function between the incident E-field and an internal induced current this object has been calibrated in laboratory using a strip-line which enables to fully control the incident EM field. We focus, here, on the need to perfectly control the whole measurement links and test setup to ensure a sufficient level of sensitivity and reproducibility.","PeriodicalId":325138,"journal":{"name":"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Reference box to control measurements of low frequency HIRF transfer functions\",\"authors\":\"W. Quenum, I. Junqua, J. Parmantier, O. Verstraete, D. Lemaire, F. Therond\",\"doi\":\"10.1109/APEMC.2015.7175372\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper addresses the issue of transfer function measurements inside a structure in High Intensity Radiated Fields environment (HIRF). In this context, a simple reference test object was designed and used as a set up verification device to be tested before HIRF measurement campaigns on aircraft. In order to obtain a reference measured transfer function between the incident E-field and an internal induced current this object has been calibrated in laboratory using a strip-line which enables to fully control the incident EM field. We focus, here, on the need to perfectly control the whole measurement links and test setup to ensure a sufficient level of sensitivity and reproducibility.\",\"PeriodicalId\":325138,\"journal\":{\"name\":\"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEMC.2015.7175372\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEMC.2015.7175372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文研究了高强度辐射场环境下结构内部传递函数的测量问题。在这种情况下,设计了一个简单的参考测试对象,并将其用作飞机上HIRF测量活动之前测试的设置验证装置。为了获得入射电磁场和内部感应电流之间的参考传递函数,该对象在实验室中使用条带线进行了校准,该条带线能够完全控制入射电磁场。在这里,我们的重点是需要完美地控制整个测量环节和测试设置,以确保足够的灵敏度和再现性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reference box to control measurements of low frequency HIRF transfer functions
This paper addresses the issue of transfer function measurements inside a structure in High Intensity Radiated Fields environment (HIRF). In this context, a simple reference test object was designed and used as a set up verification device to be tested before HIRF measurement campaigns on aircraft. In order to obtain a reference measured transfer function between the incident E-field and an internal induced current this object has been calibrated in laboratory using a strip-line which enables to fully control the incident EM field. We focus, here, on the need to perfectly control the whole measurement links and test setup to ensure a sufficient level of sensitivity and reproducibility.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信