Stewart平台的Hammerstein-Wiener模型研究

Xuewei Wang, Wensheng Zhang, Baolin Wu
{"title":"Stewart平台的Hammerstein-Wiener模型研究","authors":"Xuewei Wang, Wensheng Zhang, Baolin Wu","doi":"10.1109/ROBIO.2012.6491307","DOIUrl":null,"url":null,"abstract":"The Hammerstein-Wiener model for the Stewart platform driven by a DC motor is formulation, meanwhile the model's parameters are identified by experiments. By comparing the identification results of ARX model and Ham-merstein-Wiener model, it concludes that the Hammer-stein-Wiener model can describe the actual system's movement more accurately. The accuracy of the established Hammer-stein-Wiener model is proved by Stewart platform's single-degree of freedom (DOF) movement experiments in low frequency and small-scale (0–5 mm) range. Experimental studies show that the established model can accurately track the movement of Stewart platform. The Hammerstein-Wiener model of the Stewart platform provides a new method for the use of the Stewart platform in practical project.","PeriodicalId":426468,"journal":{"name":"2012 IEEE International Conference on Robotics and Biomimetics (ROBIO)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Hammerstein-Wiener model research for a Stewart platform\",\"authors\":\"Xuewei Wang, Wensheng Zhang, Baolin Wu\",\"doi\":\"10.1109/ROBIO.2012.6491307\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Hammerstein-Wiener model for the Stewart platform driven by a DC motor is formulation, meanwhile the model's parameters are identified by experiments. By comparing the identification results of ARX model and Ham-merstein-Wiener model, it concludes that the Hammer-stein-Wiener model can describe the actual system's movement more accurately. The accuracy of the established Hammer-stein-Wiener model is proved by Stewart platform's single-degree of freedom (DOF) movement experiments in low frequency and small-scale (0–5 mm) range. Experimental studies show that the established model can accurately track the movement of Stewart platform. The Hammerstein-Wiener model of the Stewart platform provides a new method for the use of the Stewart platform in practical project.\",\"PeriodicalId\":426468,\"journal\":{\"name\":\"2012 IEEE International Conference on Robotics and Biomimetics (ROBIO)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Conference on Robotics and Biomimetics (ROBIO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ROBIO.2012.6491307\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Conference on Robotics and Biomimetics (ROBIO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ROBIO.2012.6491307","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

建立了直流电机驱动Stewart平台的Hammerstein-Wiener模型,并通过实验对模型参数进行了辨识。通过对比ARX模型和Ham-merstein-Wiener模型的辨识结果,得出Hammer-stein-Wiener模型能更准确地描述系统的实际运动。通过Stewart平台在低频率和小尺度(0-5 mm)范围内的单自由度运动实验,验证了所建立的Hammer-stein-Wiener模型的准确性。实验研究表明,所建立的模型能够准确地跟踪Stewart平台的运动。Stewart平台的Hammerstein-Wiener模型为Stewart平台在实际工程中的应用提供了一种新的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hammerstein-Wiener model research for a Stewart platform
The Hammerstein-Wiener model for the Stewart platform driven by a DC motor is formulation, meanwhile the model's parameters are identified by experiments. By comparing the identification results of ARX model and Ham-merstein-Wiener model, it concludes that the Hammer-stein-Wiener model can describe the actual system's movement more accurately. The accuracy of the established Hammer-stein-Wiener model is proved by Stewart platform's single-degree of freedom (DOF) movement experiments in low frequency and small-scale (0–5 mm) range. Experimental studies show that the established model can accurately track the movement of Stewart platform. The Hammerstein-Wiener model of the Stewart platform provides a new method for the use of the Stewart platform in practical project.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信