并网光伏系统谐波电流孤岛检测

B. K. Jose, G. Vincent
{"title":"并网光伏系统谐波电流孤岛检测","authors":"B. K. Jose, G. Vincent","doi":"10.1109/ICCS1.2017.8325988","DOIUrl":null,"url":null,"abstract":"In this paper, an improves islanding detection technique for grid connected photovoltaic systems is proposed based on the harmonic current produced by the inverter. The inverter is controlled using constant current control scheme by injecting harmonic current signal generated from the system itself. So this detection technique has the benefits of both passive and active detection methods such as power quality enhancement and reduction of non-detection zone (NDZ) respectively. The proposal is validated through simulation studies in a single phase grid connected Photovoltaic system and the islanding operation is detected in a very short time, with reduction in the NDZ compared to the conventional current control method.","PeriodicalId":367360,"journal":{"name":"2017 IEEE International Conference on Circuits and Systems (ICCS)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Harmonic current based islanding detection for grid connected PV systems\",\"authors\":\"B. K. Jose, G. Vincent\",\"doi\":\"10.1109/ICCS1.2017.8325988\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, an improves islanding detection technique for grid connected photovoltaic systems is proposed based on the harmonic current produced by the inverter. The inverter is controlled using constant current control scheme by injecting harmonic current signal generated from the system itself. So this detection technique has the benefits of both passive and active detection methods such as power quality enhancement and reduction of non-detection zone (NDZ) respectively. The proposal is validated through simulation studies in a single phase grid connected Photovoltaic system and the islanding operation is detected in a very short time, with reduction in the NDZ compared to the conventional current control method.\",\"PeriodicalId\":367360,\"journal\":{\"name\":\"2017 IEEE International Conference on Circuits and Systems (ICCS)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE International Conference on Circuits and Systems (ICCS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCS1.2017.8325988\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE International Conference on Circuits and Systems (ICCS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCS1.2017.8325988","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

本文提出了一种改进的基于逆变器谐波电流的并网光伏系统孤岛检测技术。逆变器采用恒流控制方案,通过注入系统自身产生的谐波电流信号对逆变器进行控制。因此,该检测技术具有提高电能质量和减小非检测区(NDZ)等被动检测方法和主动检测方法的优点。通过对单相并网光伏系统的仿真研究,验证了该方案的有效性,在很短的时间内检测到孤岛运行,与传统的电流控制方法相比,降低了NDZ。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Harmonic current based islanding detection for grid connected PV systems
In this paper, an improves islanding detection technique for grid connected photovoltaic systems is proposed based on the harmonic current produced by the inverter. The inverter is controlled using constant current control scheme by injecting harmonic current signal generated from the system itself. So this detection technique has the benefits of both passive and active detection methods such as power quality enhancement and reduction of non-detection zone (NDZ) respectively. The proposal is validated through simulation studies in a single phase grid connected Photovoltaic system and the islanding operation is detected in a very short time, with reduction in the NDZ compared to the conventional current control method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信