I. Lopez-Calle, A. Sirin, H. Andersson, M. Kerényi, J. Gonzalez, C. Poivey, L. Bonora, E. Muñoz, M. Domínguez, G. Fernández
{"title":"JUICE 8通道超快充电前置放大器ASIC的pai - x SEE测试","authors":"I. Lopez-Calle, A. Sirin, H. Andersson, M. Kerényi, J. Gonzalez, C. Poivey, L. Bonora, E. Muñoz, M. Domínguez, G. Fernández","doi":"10.1109/RADECS.2017.8696133","DOIUrl":null,"url":null,"abstract":"SEE testing carried out on PADI-X charge amplifier ASIC within ESA-JUICE mission context. Not SEL or permanent damage was detected. Full SEFI/CEM cross sections are provided with an ion LET range of 1-63 MeV.cm2/mg.","PeriodicalId":223580,"journal":{"name":"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"SEE Testing on PADI-X for JUICE 8-Channel Ultrafast Charge Pre-Amplifier ASIC\",\"authors\":\"I. Lopez-Calle, A. Sirin, H. Andersson, M. Kerényi, J. Gonzalez, C. Poivey, L. Bonora, E. Muñoz, M. Domínguez, G. Fernández\",\"doi\":\"10.1109/RADECS.2017.8696133\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"SEE testing carried out on PADI-X charge amplifier ASIC within ESA-JUICE mission context. Not SEL or permanent damage was detected. Full SEFI/CEM cross sections are provided with an ion LET range of 1-63 MeV.cm2/mg.\",\"PeriodicalId\":223580,\"journal\":{\"name\":\"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RADECS.2017.8696133\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RADECS.2017.8696133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
SEE Testing on PADI-X for JUICE 8-Channel Ultrafast Charge Pre-Amplifier ASIC
SEE testing carried out on PADI-X charge amplifier ASIC within ESA-JUICE mission context. Not SEL or permanent damage was detected. Full SEFI/CEM cross sections are provided with an ion LET range of 1-63 MeV.cm2/mg.