{"title":"基于推力和扭矩的机器人钻井系统实时CT值估计方法","authors":"K. Yu, Sho Iwata, K. Ohnishi, H. Kawana, S. Usuda","doi":"10.1109/IECON.2013.6699727","DOIUrl":null,"url":null,"abstract":"An estimation of bone density is important for dental implant. CT value has been used in clinical and diagnostic as a quantitative evaluation method of bone density. In this paper, a method for estimating the CT value is proposed by modeling the relation between the cutting force and the CT value. The cutting force is calculated by the thrust force of the linear motor and the torque of the rotary motor. The estimated CT value can be obtained in real time by comparing between the force from reaction force observer and the formula of CT value with the pre-estimated parameters. The validity of the proposal was confirmed through experiments using wood mentioned in Misch's bone density classification. The experimental results indicated that the error of CT value estimation was ±91 HU and the estimation accuracy was 84 %.","PeriodicalId":237327,"journal":{"name":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Real-time CT value estimation method for robotic drilling system based on thrust force and torque\",\"authors\":\"K. Yu, Sho Iwata, K. Ohnishi, H. Kawana, S. Usuda\",\"doi\":\"10.1109/IECON.2013.6699727\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An estimation of bone density is important for dental implant. CT value has been used in clinical and diagnostic as a quantitative evaluation method of bone density. In this paper, a method for estimating the CT value is proposed by modeling the relation between the cutting force and the CT value. The cutting force is calculated by the thrust force of the linear motor and the torque of the rotary motor. The estimated CT value can be obtained in real time by comparing between the force from reaction force observer and the formula of CT value with the pre-estimated parameters. The validity of the proposal was confirmed through experiments using wood mentioned in Misch's bone density classification. The experimental results indicated that the error of CT value estimation was ±91 HU and the estimation accuracy was 84 %.\",\"PeriodicalId\":237327,\"journal\":{\"name\":\"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.2013.6699727\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2013.6699727","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Real-time CT value estimation method for robotic drilling system based on thrust force and torque
An estimation of bone density is important for dental implant. CT value has been used in clinical and diagnostic as a quantitative evaluation method of bone density. In this paper, a method for estimating the CT value is proposed by modeling the relation between the cutting force and the CT value. The cutting force is calculated by the thrust force of the linear motor and the torque of the rotary motor. The estimated CT value can be obtained in real time by comparing between the force from reaction force observer and the formula of CT value with the pre-estimated parameters. The validity of the proposal was confirmed through experiments using wood mentioned in Misch's bone density classification. The experimental results indicated that the error of CT value estimation was ±91 HU and the estimation accuracy was 84 %.