基于Contourlet的PCO量化系统

Muhammad Reza Pourshahabi, H. Pourreza, O. Findl, R. D. Kakhki, W. Buehl
{"title":"基于Contourlet的PCO量化系统","authors":"Muhammad Reza Pourshahabi, H. Pourreza, O. Findl, R. D. Kakhki, W. Buehl","doi":"10.1109/SoCPaR.2009.86","DOIUrl":null,"url":null,"abstract":"Nowadays, Posterior Capsule Opacification (PCO)is a common postoperative complication of cataract surgery. The rate of incidence and the intensity of PCO are affected by factors such as type and shape of implanted intraocular lens(IOL), cataract surgical techniques and etc. Clinical quantification of PCO is so subjective that evaluating the effects of these factors on PCO are varying among studies. The need for a reliable and efficient automated PCO quantification system is highly desired and many researchers tried to design such a system till now. In this paper a new fully automated Contourlet based PCO quantification system (CPCO) is presented. Comparing this system with other subjective and objective systems shows the reliability and correctness of CPCO system.","PeriodicalId":284743,"journal":{"name":"2009 International Conference of Soft Computing and Pattern Recognition","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"CPCO: Contourlet Based PCO Quantification System\",\"authors\":\"Muhammad Reza Pourshahabi, H. Pourreza, O. Findl, R. D. Kakhki, W. Buehl\",\"doi\":\"10.1109/SoCPaR.2009.86\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Nowadays, Posterior Capsule Opacification (PCO)is a common postoperative complication of cataract surgery. The rate of incidence and the intensity of PCO are affected by factors such as type and shape of implanted intraocular lens(IOL), cataract surgical techniques and etc. Clinical quantification of PCO is so subjective that evaluating the effects of these factors on PCO are varying among studies. The need for a reliable and efficient automated PCO quantification system is highly desired and many researchers tried to design such a system till now. In this paper a new fully automated Contourlet based PCO quantification system (CPCO) is presented. Comparing this system with other subjective and objective systems shows the reliability and correctness of CPCO system.\",\"PeriodicalId\":284743,\"journal\":{\"name\":\"2009 International Conference of Soft Computing and Pattern Recognition\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Conference of Soft Computing and Pattern Recognition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SoCPaR.2009.86\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference of Soft Computing and Pattern Recognition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SoCPaR.2009.86","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

目前,后囊膜混浊是白内障手术后常见的并发症。白内障后发的发生率和强度受人工晶状体类型、形状、白内障手术技术等因素的影响。PCO的临床量化是非常主观的,因此评估这些因素对PCO的影响在不同的研究中是不同的。人们迫切需要一个可靠、高效的PCO自动化定量系统,许多研究人员一直在尝试设计这样的系统。本文提出了一种基于Contourlet的全自动PCO定量系统。将该系统与其他主客观系统进行比较,证明了CPCO系统的可靠性和正确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
CPCO: Contourlet Based PCO Quantification System
Nowadays, Posterior Capsule Opacification (PCO)is a common postoperative complication of cataract surgery. The rate of incidence and the intensity of PCO are affected by factors such as type and shape of implanted intraocular lens(IOL), cataract surgical techniques and etc. Clinical quantification of PCO is so subjective that evaluating the effects of these factors on PCO are varying among studies. The need for a reliable and efficient automated PCO quantification system is highly desired and many researchers tried to design such a system till now. In this paper a new fully automated Contourlet based PCO quantification system (CPCO) is presented. Comparing this system with other subjective and objective systems shows the reliability and correctness of CPCO system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信