大风侵彻下电力系统模型稳定性评估

T. Geetha, V. Jayashankar
{"title":"大风侵彻下电力系统模型稳定性评估","authors":"T. Geetha, V. Jayashankar","doi":"10.1109/ICPST.2008.4745226","DOIUrl":null,"url":null,"abstract":"For grids of low X/R ratios voltage control through active power is effective in reducing the voltage at the point of interconnection of wind farms to grid. Active power voltage control can be achieved using energy storage schemes or inter connectors. In this paper we propose variable frequency transformers (VFT) as an effective means of interconnecting synchronous or asynchronous regions to enhance wind penetration. It is shown that the steady state stability limits of the system are improved with VFT as inter connectors. Also the performance of the VFT under open circuit and short circuit conditions are evaluated.","PeriodicalId":107016,"journal":{"name":"2008 Joint International Conference on Power System Technology and IEEE Power India Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Stability Assessment of Power System Models For Higher Wind Penetration\",\"authors\":\"T. Geetha, V. Jayashankar\",\"doi\":\"10.1109/ICPST.2008.4745226\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For grids of low X/R ratios voltage control through active power is effective in reducing the voltage at the point of interconnection of wind farms to grid. Active power voltage control can be achieved using energy storage schemes or inter connectors. In this paper we propose variable frequency transformers (VFT) as an effective means of interconnecting synchronous or asynchronous regions to enhance wind penetration. It is shown that the steady state stability limits of the system are improved with VFT as inter connectors. Also the performance of the VFT under open circuit and short circuit conditions are evaluated.\",\"PeriodicalId\":107016,\"journal\":{\"name\":\"2008 Joint International Conference on Power System Technology and IEEE Power India Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Joint International Conference on Power System Technology and IEEE Power India Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPST.2008.4745226\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Joint International Conference on Power System Technology and IEEE Power India Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST.2008.4745226","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

对于低X/R比的电网,通过有功功率进行电压控制可以有效地降低风电场与电网互连点的电压。有功电压控制可以通过储能方案或内部连接器来实现。在本文中,我们提出变频变压器(VFT)作为一种有效的手段,互联同步或异步区域,以提高风穿透。结果表明,采用VFT作为互连体,系统的稳态稳定极限得到了提高。并对该系统在开路和短路条件下的性能进行了评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Stability Assessment of Power System Models For Higher Wind Penetration
For grids of low X/R ratios voltage control through active power is effective in reducing the voltage at the point of interconnection of wind farms to grid. Active power voltage control can be achieved using energy storage schemes or inter connectors. In this paper we propose variable frequency transformers (VFT) as an effective means of interconnecting synchronous or asynchronous regions to enhance wind penetration. It is shown that the steady state stability limits of the system are improved with VFT as inter connectors. Also the performance of the VFT under open circuit and short circuit conditions are evaluated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信