动态技术在电迁移动力学研究中的应用

R. Pasco, J. A. Schwarz
{"title":"动态技术在电迁移动力学研究中的应用","authors":"R. Pasco, J. A. Schwarz","doi":"10.1109/IRPS.1983.361955","DOIUrl":null,"url":null,"abstract":"A temperature-ramp technique is presented that enables determination of the kinetic parameters for electromigration processes. With this method, pre-exponentials and activation energies can be measured in a single experiment requiring a few hours. The technique is applicable to both practical and fundamental studies of electromigration. For example, in terms of the former, reliability factors for conductor lifetimes can be readily determined. As far as the latter, new conductor compositions can be rapidly screened to ascertain their electromigration behavior. Temperature-ramp Resistance Analysis to Characterize Electromigration (TRACE) has been applied to thin-film aluminum conductors. Results have yielded activation energies in agreement with literature values. Furthermore, the TRACE results have been used, along with resistivity results from the literature, to determine the current density effect on the pre-exponential factor. The value of the current density exponent thus determined is in accord with the range reported in the literature for Mean Time to Failure (MTF) experiments. The TRACE technique has also been used to determine the effect of hydrogen ambients on electromigration damage (EMD) kinetics for both aluminum and Al-2%Cu thin-film conductors. The effects of hydrogen ambients on EMD kinetics have been determined to be more complex than suggested by prior results in the literature.","PeriodicalId":334813,"journal":{"name":"21st International Reliability Physics Symposium","volume":"108 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1983-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"The Application of a Dynamic Technique to the Study of Electromigration Kinetics\",\"authors\":\"R. Pasco, J. A. Schwarz\",\"doi\":\"10.1109/IRPS.1983.361955\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A temperature-ramp technique is presented that enables determination of the kinetic parameters for electromigration processes. With this method, pre-exponentials and activation energies can be measured in a single experiment requiring a few hours. The technique is applicable to both practical and fundamental studies of electromigration. For example, in terms of the former, reliability factors for conductor lifetimes can be readily determined. As far as the latter, new conductor compositions can be rapidly screened to ascertain their electromigration behavior. Temperature-ramp Resistance Analysis to Characterize Electromigration (TRACE) has been applied to thin-film aluminum conductors. Results have yielded activation energies in agreement with literature values. Furthermore, the TRACE results have been used, along with resistivity results from the literature, to determine the current density effect on the pre-exponential factor. The value of the current density exponent thus determined is in accord with the range reported in the literature for Mean Time to Failure (MTF) experiments. The TRACE technique has also been used to determine the effect of hydrogen ambients on electromigration damage (EMD) kinetics for both aluminum and Al-2%Cu thin-film conductors. The effects of hydrogen ambients on EMD kinetics have been determined to be more complex than suggested by prior results in the literature.\",\"PeriodicalId\":334813,\"journal\":{\"name\":\"21st International Reliability Physics Symposium\",\"volume\":\"108 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1983-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"21st International Reliability Physics Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IRPS.1983.361955\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"21st International Reliability Physics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRPS.1983.361955","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

提出了一种温度斜坡技术,可以确定电迁移过程的动力学参数。用这种方法,可以在几个小时的单次实验中测量出指数前指数和活化能。该技术适用于电迁移的实际和基础研究。例如,就前者而言,导体寿命的可靠性因素可以很容易地确定。就后者而言,新的导体组合物可以快速筛选以确定其电迁移行为。温度斜坡电阻分析表征电迁移(TRACE)已应用于薄膜铝导体。结果得到的活化能与文献值一致。此外,TRACE结果与文献中的电阻率结果一起用于确定电流密度对指数前因子的影响。由此确定的电流密度指数的值与文献中报道的平均失效时间(MTF)实验的范围一致。TRACE技术还用于确定氢环境对铝和Al-2%Cu薄膜导体电迁移损伤(EMD)动力学的影响。氢环境对EMD动力学的影响已被确定为比文献中先前的结果所建议的更复杂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Application of a Dynamic Technique to the Study of Electromigration Kinetics
A temperature-ramp technique is presented that enables determination of the kinetic parameters for electromigration processes. With this method, pre-exponentials and activation energies can be measured in a single experiment requiring a few hours. The technique is applicable to both practical and fundamental studies of electromigration. For example, in terms of the former, reliability factors for conductor lifetimes can be readily determined. As far as the latter, new conductor compositions can be rapidly screened to ascertain their electromigration behavior. Temperature-ramp Resistance Analysis to Characterize Electromigration (TRACE) has been applied to thin-film aluminum conductors. Results have yielded activation energies in agreement with literature values. Furthermore, the TRACE results have been used, along with resistivity results from the literature, to determine the current density effect on the pre-exponential factor. The value of the current density exponent thus determined is in accord with the range reported in the literature for Mean Time to Failure (MTF) experiments. The TRACE technique has also been used to determine the effect of hydrogen ambients on electromigration damage (EMD) kinetics for both aluminum and Al-2%Cu thin-film conductors. The effects of hydrogen ambients on EMD kinetics have been determined to be more complex than suggested by prior results in the literature.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信