生物信号研究平台,学术研究和教育实验室

A. Marcu, N. Codreanu, D. Taralunga
{"title":"生物信号研究平台,学术研究和教育实验室","authors":"A. Marcu, N. Codreanu, D. Taralunga","doi":"10.1109/SIITME.2015.7342315","DOIUrl":null,"url":null,"abstract":"Bio-potentials recorded via electrodes placed on the body surface, provide information about the behavior and the health status of the human body. Thus, it is used for the diagnosis and monitoring purposes. The measurement of these electric signals offers knowledge about the physiology of various organs. Developing a bio-potentials acquisition system is a challenge for both system and Printed Circuit Board (PCB) designers because the investigated signals are very small and the equipment designed to acquire them is sensitive to different factors: operating conditions, electrostatic discharge (ESD), power supply filtering, communication signals etc. The paper presents a first attempt to design and realize a bio-signals acquisition system, highlighting the problems encountered and offering possible solutions. Finally, the need for a very careful PCB design is a good challenge for those interested in advanced PCB development.","PeriodicalId":174623,"journal":{"name":"2015 IEEE 21st International Symposium for Design and Technology in Electronic Packaging (SIITME)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Bio-signals investigation platform for academic research and education laboratories\",\"authors\":\"A. Marcu, N. Codreanu, D. Taralunga\",\"doi\":\"10.1109/SIITME.2015.7342315\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Bio-potentials recorded via electrodes placed on the body surface, provide information about the behavior and the health status of the human body. Thus, it is used for the diagnosis and monitoring purposes. The measurement of these electric signals offers knowledge about the physiology of various organs. Developing a bio-potentials acquisition system is a challenge for both system and Printed Circuit Board (PCB) designers because the investigated signals are very small and the equipment designed to acquire them is sensitive to different factors: operating conditions, electrostatic discharge (ESD), power supply filtering, communication signals etc. The paper presents a first attempt to design and realize a bio-signals acquisition system, highlighting the problems encountered and offering possible solutions. Finally, the need for a very careful PCB design is a good challenge for those interested in advanced PCB development.\",\"PeriodicalId\":174623,\"journal\":{\"name\":\"2015 IEEE 21st International Symposium for Design and Technology in Electronic Packaging (SIITME)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 21st International Symposium for Design and Technology in Electronic Packaging (SIITME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIITME.2015.7342315\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 21st International Symposium for Design and Technology in Electronic Packaging (SIITME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIITME.2015.7342315","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

生物电位通过放置在体表的电极记录下来,提供有关人体行为和健康状况的信息。因此,它用于诊断和监测目的。对这些电信号的测量提供了有关各种器官生理学的知识。开发生物电位采集系统对系统和印刷电路板(PCB)设计人员来说都是一个挑战,因为所研究的信号非常小,而用于采集这些信号的设备对不同的因素很敏感:工作条件、静电放电(ESD)、电源滤波、通信信号等。本文首次尝试设计和实现了一个生物信号采集系统,重点介绍了遇到的问题,并提出了可能的解决方案。最后,对于那些对高级PCB开发感兴趣的人来说,需要非常仔细的PCB设计是一个很好的挑战。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Bio-signals investigation platform for academic research and education laboratories
Bio-potentials recorded via electrodes placed on the body surface, provide information about the behavior and the health status of the human body. Thus, it is used for the diagnosis and monitoring purposes. The measurement of these electric signals offers knowledge about the physiology of various organs. Developing a bio-potentials acquisition system is a challenge for both system and Printed Circuit Board (PCB) designers because the investigated signals are very small and the equipment designed to acquire them is sensitive to different factors: operating conditions, electrostatic discharge (ESD), power supply filtering, communication signals etc. The paper presents a first attempt to design and realize a bio-signals acquisition system, highlighting the problems encountered and offering possible solutions. Finally, the need for a very careful PCB design is a good challenge for those interested in advanced PCB development.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信