球面近场测试设备中交叉偏振测量的挑战

L. Shafai, K. Oueng, Shantnu R. Mishra
{"title":"球面近场测试设备中交叉偏振测量的挑战","authors":"L. Shafai, K. Oueng, Shantnu R. Mishra","doi":"10.1109/ANTEMURSI.2009.4805111","DOIUrl":null,"url":null,"abstract":"Accurate cross polarization measurements present challenges to a test facility due to the difficulty of resolving low amplitude levels typically observed in these radiation patterns. The effectiveness of the near-field measurement set-up and acquisition, in addition to the post-processing of the collected near-field data are critical to the success of the measurement. This paper discusses recent experiences at resolving low-cross polarization levels in the spherical near-field facility at the Canadia Space Agency's David Florida Laboratory. Chamber alignment, measurement, and processing procedures are discussed and the results presented for characterization of a corrugated cylindrical waveguide.","PeriodicalId":190053,"journal":{"name":"2009 13th International Symposium on Antenna Technology and Applied Electromagnetics and the Canadian Radio Science Meeting","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cross-polarization measurement chalenges in a spherical near-field test facility\",\"authors\":\"L. Shafai, K. Oueng, Shantnu R. Mishra\",\"doi\":\"10.1109/ANTEMURSI.2009.4805111\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accurate cross polarization measurements present challenges to a test facility due to the difficulty of resolving low amplitude levels typically observed in these radiation patterns. The effectiveness of the near-field measurement set-up and acquisition, in addition to the post-processing of the collected near-field data are critical to the success of the measurement. This paper discusses recent experiences at resolving low-cross polarization levels in the spherical near-field facility at the Canadia Space Agency's David Florida Laboratory. Chamber alignment, measurement, and processing procedures are discussed and the results presented for characterization of a corrugated cylindrical waveguide.\",\"PeriodicalId\":190053,\"journal\":{\"name\":\"2009 13th International Symposium on Antenna Technology and Applied Electromagnetics and the Canadian Radio Science Meeting\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-03-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 13th International Symposium on Antenna Technology and Applied Electromagnetics and the Canadian Radio Science Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ANTEMURSI.2009.4805111\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 13th International Symposium on Antenna Technology and Applied Electromagnetics and the Canadian Radio Science Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ANTEMURSI.2009.4805111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于难以分辨在这些辐射模式中通常观察到的低振幅水平,因此准确的交叉偏振测量对测试设施提出了挑战。近场测量的设置和采集的有效性,以及采集到的近场数据的后处理对测量的成功至关重要。本文讨论了在加拿大航天局大卫佛罗里达实验室的球形近场设备中解决低交叉偏振水平的最新经验。讨论了腔室对准、测量和处理程序,并给出了波纹圆柱波导表征的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cross-polarization measurement chalenges in a spherical near-field test facility
Accurate cross polarization measurements present challenges to a test facility due to the difficulty of resolving low amplitude levels typically observed in these radiation patterns. The effectiveness of the near-field measurement set-up and acquisition, in addition to the post-processing of the collected near-field data are critical to the success of the measurement. This paper discusses recent experiences at resolving low-cross polarization levels in the spherical near-field facility at the Canadia Space Agency's David Florida Laboratory. Chamber alignment, measurement, and processing procedures are discussed and the results presented for characterization of a corrugated cylindrical waveguide.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信