{"title":"电弧诊断与通用数学模型的发展","authors":"A. Sawicki","doi":"10.17729/ebis.2021.6/5","DOIUrl":null,"url":null,"abstract":"The article presents universal mathematical static current-voltage characteristics- based models of electric arc and indicates primary issues concerned with arc diagnostics related to the determination of the above-named models. Particular attention was paid to the experimental determination of AC-powered arc voltage. Diagnostics-related purposes involved the use of bridge systems with one or two sources of current. Computer-aided simulations involving sinusoidal and trapezoidal current-based excitations made it possible to demonstrate the possibility of obtaining minimum values of bridge unbalance voltage. Such a condition indicated the proper determination of AC-powered arc ignition voltage.","PeriodicalId":184101,"journal":{"name":"Biuletyn Instytutu Spawalnictwa","volume":"734 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostics of Electric Arc versus the Development of Universal Mathematical Models\",\"authors\":\"A. Sawicki\",\"doi\":\"10.17729/ebis.2021.6/5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article presents universal mathematical static current-voltage characteristics- based models of electric arc and indicates primary issues concerned with arc diagnostics related to the determination of the above-named models. Particular attention was paid to the experimental determination of AC-powered arc voltage. Diagnostics-related purposes involved the use of bridge systems with one or two sources of current. Computer-aided simulations involving sinusoidal and trapezoidal current-based excitations made it possible to demonstrate the possibility of obtaining minimum values of bridge unbalance voltage. Such a condition indicated the proper determination of AC-powered arc ignition voltage.\",\"PeriodicalId\":184101,\"journal\":{\"name\":\"Biuletyn Instytutu Spawalnictwa\",\"volume\":\"734 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biuletyn Instytutu Spawalnictwa\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17729/ebis.2021.6/5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biuletyn Instytutu Spawalnictwa","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17729/ebis.2021.6/5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Diagnostics of Electric Arc versus the Development of Universal Mathematical Models
The article presents universal mathematical static current-voltage characteristics- based models of electric arc and indicates primary issues concerned with arc diagnostics related to the determination of the above-named models. Particular attention was paid to the experimental determination of AC-powered arc voltage. Diagnostics-related purposes involved the use of bridge systems with one or two sources of current. Computer-aided simulations involving sinusoidal and trapezoidal current-based excitations made it possible to demonstrate the possibility of obtaining minimum values of bridge unbalance voltage. Such a condition indicated the proper determination of AC-powered arc ignition voltage.