{"title":"介绍了一个Matlab图形用户界面,用于分析高压变电站暂态过程中的应力","authors":"M. Brojboiu, V. Ivanov","doi":"10.1109/SIELMEN.2017.8123308","DOIUrl":null,"url":null,"abstract":"In this paper is presented a Matlab graphical user interface useful to compute the thermal and dielectric stresses which means the parameters computation of the short circuit currents or transient recovery voltages which appear during the fault regimes in the high voltage networks. The analysis of the electrical stresses is carried out for the high voltage substations from ST Craiova. The Matlab GUI is developed starting from the automatic computation program which was realized within the research contract with the Transelectrica SA Branch Craiova [1]. The results obtained within this contract were previously presented in the [2], [3], [4], [5]. The computation algorithm is based on the references in the field [6…12]. The GUI can be used for any other high voltage substation whose rated parameters are known.","PeriodicalId":403279,"journal":{"name":"2017 International Conference on Electromechanical and Power Systems (SIELMEN)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"About a Matlab graphical user interface to analyze stresses during the transient regimes in the high voltage substations\",\"authors\":\"M. Brojboiu, V. Ivanov\",\"doi\":\"10.1109/SIELMEN.2017.8123308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper is presented a Matlab graphical user interface useful to compute the thermal and dielectric stresses which means the parameters computation of the short circuit currents or transient recovery voltages which appear during the fault regimes in the high voltage networks. The analysis of the electrical stresses is carried out for the high voltage substations from ST Craiova. The Matlab GUI is developed starting from the automatic computation program which was realized within the research contract with the Transelectrica SA Branch Craiova [1]. The results obtained within this contract were previously presented in the [2], [3], [4], [5]. The computation algorithm is based on the references in the field [6…12]. The GUI can be used for any other high voltage substation whose rated parameters are known.\",\"PeriodicalId\":403279,\"journal\":{\"name\":\"2017 International Conference on Electromechanical and Power Systems (SIELMEN)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Conference on Electromechanical and Power Systems (SIELMEN)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIELMEN.2017.8123308\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Electromechanical and Power Systems (SIELMEN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIELMEN.2017.8123308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本文提出了一个用于计算高压电网在故障状态下出现的短路电流或暂态恢复电压的热应力和介电应力的Matlab图形用户界面。对ST Craiova公司的高压变电站进行了电气应力分析。Matlab GUI是从自动计算程序开始开发的,该程序是在与transelecica SA Branch Craiova的研究合同中实现的[1]。在此合同中获得的结果已在先前的文献[2]、[3]、[4]、[5]中提出。计算算法基于该领域的文献[6…12]。该GUI可用于已知额定参数的任何其他高压变电站。
About a Matlab graphical user interface to analyze stresses during the transient regimes in the high voltage substations
In this paper is presented a Matlab graphical user interface useful to compute the thermal and dielectric stresses which means the parameters computation of the short circuit currents or transient recovery voltages which appear during the fault regimes in the high voltage networks. The analysis of the electrical stresses is carried out for the high voltage substations from ST Craiova. The Matlab GUI is developed starting from the automatic computation program which was realized within the research contract with the Transelectrica SA Branch Craiova [1]. The results obtained within this contract were previously presented in the [2], [3], [4], [5]. The computation algorithm is based on the references in the field [6…12]. The GUI can be used for any other high voltage substation whose rated parameters are known.