三相三线并联有源滤波器电流控制新策略

O. Kukrer, H. Komurcugil
{"title":"三相三线并联有源滤波器电流控制新策略","authors":"O. Kukrer, H. Komurcugil","doi":"10.1109/ISIE.2008.4676890","DOIUrl":null,"url":null,"abstract":"A new current control strategy is proposed for the control of three-phase three-wire shunt active power filters. In this strategy it is sufficient to measure the source voltage and the load currents. Analyses of the balanced nonlinear and unbalanced linear load cases are performed. Simulations are performed for these cases as well as for a nonlinear load drawing quasi-square-wave currents from the mains. Stability analysis is also performed to determine the stability region of the proportional-integral controller gains used in the voltage control loop. Simulation studies show that the proposed strategy is quite effective in eliminating harmonics, compensating for reactive power and also balancing unbalanced loads. It is simpler than most strategies proposed in the literature.","PeriodicalId":262939,"journal":{"name":"2008 IEEE International Symposium on Industrial Electronics","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A new current control strategy for three-phase three wire shunt active power filters\",\"authors\":\"O. Kukrer, H. Komurcugil\",\"doi\":\"10.1109/ISIE.2008.4676890\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new current control strategy is proposed for the control of three-phase three-wire shunt active power filters. In this strategy it is sufficient to measure the source voltage and the load currents. Analyses of the balanced nonlinear and unbalanced linear load cases are performed. Simulations are performed for these cases as well as for a nonlinear load drawing quasi-square-wave currents from the mains. Stability analysis is also performed to determine the stability region of the proportional-integral controller gains used in the voltage control loop. Simulation studies show that the proposed strategy is quite effective in eliminating harmonics, compensating for reactive power and also balancing unbalanced loads. It is simpler than most strategies proposed in the literature.\",\"PeriodicalId\":262939,\"journal\":{\"name\":\"2008 IEEE International Symposium on Industrial Electronics\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 IEEE International Symposium on Industrial Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2008.4676890\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE International Symposium on Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2008.4676890","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

针对三相三线并联有源滤波器的控制问题,提出了一种新的电流控制策略。在这种策略中,测量源电压和负载电流就足够了。对平衡非线性载荷和不平衡线性载荷进行了分析。对这些情况进行了仿真,并对非线性负载从市电汲取准方波电流进行了仿真。还进行了稳定性分析,以确定电压控制回路中使用的比例积分控制器增益的稳定区域。仿真研究表明,该策略在消除谐波、补偿无功功率和平衡不平衡负载方面具有较好的效果。它比文献中提出的大多数策略更简单。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A new current control strategy for three-phase three wire shunt active power filters
A new current control strategy is proposed for the control of three-phase three-wire shunt active power filters. In this strategy it is sufficient to measure the source voltage and the load currents. Analyses of the balanced nonlinear and unbalanced linear load cases are performed. Simulations are performed for these cases as well as for a nonlinear load drawing quasi-square-wave currents from the mains. Stability analysis is also performed to determine the stability region of the proportional-integral controller gains used in the voltage control loop. Simulation studies show that the proposed strategy is quite effective in eliminating harmonics, compensating for reactive power and also balancing unbalanced loads. It is simpler than most strategies proposed in the literature.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信