R. Matsuura, T. Sugiyama, T. Takeshita, Y. Tadano, Shizunori Hamada, H. Kubo
{"title":"电流控制IPMSM避免电压饱和,以改变频率和振幅的振动转矩参考","authors":"R. Matsuura, T. Sugiyama, T. Takeshita, Y. Tadano, Shizunori Hamada, H. Kubo","doi":"10.1109/PEDS.2017.8289276","DOIUrl":null,"url":null,"abstract":"This paper presents the vibration torque control an IPMSM to avoid the output voltage saturation of the inverter in order to reduce the copper loss. The proposed control of the vibration torque has the feedforward control for fast response of the reference torque change and the feedback control for the parameter error compensation. The effectiveness of proposed control method has been verified by experiments.","PeriodicalId":411916,"journal":{"name":"2017 IEEE 12th International Conference on Power Electronics and Drive Systems (PEDS)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Current control of IPMSM to avoid voltage saturation for changing frequency and amplitude of vibration torque reference\",\"authors\":\"R. Matsuura, T. Sugiyama, T. Takeshita, Y. Tadano, Shizunori Hamada, H. Kubo\",\"doi\":\"10.1109/PEDS.2017.8289276\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the vibration torque control an IPMSM to avoid the output voltage saturation of the inverter in order to reduce the copper loss. The proposed control of the vibration torque has the feedforward control for fast response of the reference torque change and the feedback control for the parameter error compensation. The effectiveness of proposed control method has been verified by experiments.\",\"PeriodicalId\":411916,\"journal\":{\"name\":\"2017 IEEE 12th International Conference on Power Electronics and Drive Systems (PEDS)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE 12th International Conference on Power Electronics and Drive Systems (PEDS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDS.2017.8289276\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 12th International Conference on Power Electronics and Drive Systems (PEDS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.2017.8289276","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Current control of IPMSM to avoid voltage saturation for changing frequency and amplitude of vibration torque reference
This paper presents the vibration torque control an IPMSM to avoid the output voltage saturation of the inverter in order to reduce the copper loss. The proposed control of the vibration torque has the feedforward control for fast response of the reference torque change and the feedback control for the parameter error compensation. The effectiveness of proposed control method has been verified by experiments.