C. Lertsatitthanakorn, J. Hirunlabh, J. Khedari, H. Scherrer
{"title":"自由对流热电空调的制冷性能","authors":"C. Lertsatitthanakorn, J. Hirunlabh, J. Khedari, H. Scherrer","doi":"10.1109/ICT.2001.979928","DOIUrl":null,"url":null,"abstract":"In this paper, a lab-scale investigation of the cooling performance of a free convected thermoelectric (TE) air conditioner is reported. Two types of heat exchangers were considered: a free convected vertical, rectangular fin heat exchanger at the cold side; and a force convected skive fin heat exchanger at the hot side. A computer model developed earlier for predicting the cooling performance of free convected TE air conditioner was used in the design phase. An experimental set-up was built to study the cooling performance under various operating conditions. Seven TE modules (Tianjin Lantian model TEC1-12708) were used. The volume of the chamber was about 0.024 m/sup 3/. The effects of varying the supply voltage and airflow rate of a skive fin heat exchanger were analyzed.","PeriodicalId":203601,"journal":{"name":"Proceedings ICT2001. 20 International Conference on Thermoelectrics (Cat. No.01TH8589)","volume":"140 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Cooling performance of free convected thermoelectric air conditioner\",\"authors\":\"C. Lertsatitthanakorn, J. Hirunlabh, J. Khedari, H. Scherrer\",\"doi\":\"10.1109/ICT.2001.979928\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a lab-scale investigation of the cooling performance of a free convected thermoelectric (TE) air conditioner is reported. Two types of heat exchangers were considered: a free convected vertical, rectangular fin heat exchanger at the cold side; and a force convected skive fin heat exchanger at the hot side. A computer model developed earlier for predicting the cooling performance of free convected TE air conditioner was used in the design phase. An experimental set-up was built to study the cooling performance under various operating conditions. Seven TE modules (Tianjin Lantian model TEC1-12708) were used. The volume of the chamber was about 0.024 m/sup 3/. The effects of varying the supply voltage and airflow rate of a skive fin heat exchanger were analyzed.\",\"PeriodicalId\":203601,\"journal\":{\"name\":\"Proceedings ICT2001. 20 International Conference on Thermoelectrics (Cat. No.01TH8589)\",\"volume\":\"140 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings ICT2001. 20 International Conference on Thermoelectrics (Cat. No.01TH8589)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICT.2001.979928\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings ICT2001. 20 International Conference on Thermoelectrics (Cat. No.01TH8589)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICT.2001.979928","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Cooling performance of free convected thermoelectric air conditioner
In this paper, a lab-scale investigation of the cooling performance of a free convected thermoelectric (TE) air conditioner is reported. Two types of heat exchangers were considered: a free convected vertical, rectangular fin heat exchanger at the cold side; and a force convected skive fin heat exchanger at the hot side. A computer model developed earlier for predicting the cooling performance of free convected TE air conditioner was used in the design phase. An experimental set-up was built to study the cooling performance under various operating conditions. Seven TE modules (Tianjin Lantian model TEC1-12708) were used. The volume of the chamber was about 0.024 m/sup 3/. The effects of varying the supply voltage and airflow rate of a skive fin heat exchanger were analyzed.