S. Tedjini, S. Gaoua, R. Touhami, M. Yagoub, A. Bellaouar
{"title":"DCT载波泄漏校正","authors":"S. Tedjini, S. Gaoua, R. Touhami, M. Yagoub, A. Bellaouar","doi":"10.1109/ICSCS.2009.5414149","DOIUrl":null,"url":null,"abstract":"In this paper, an improved version of the digital calibration method for carrier leakage, which is caused by the DC offset on direct conversion transmitter, is proposed. We have used a power detector for estimating the DC offset. After, we have injected a compensation voltage for eliminating this DC offset. In order to validate our technique, a new direct conversion transmitter that operates at 2GHz, is proposed. The simulation and the implementation of the calibration were performed using the Agilent - ADS software.","PeriodicalId":300247,"journal":{"name":"2009 Mediterrannean Microwave Symposium (MMS)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Carrier leakage calibration in DCT\",\"authors\":\"S. Tedjini, S. Gaoua, R. Touhami, M. Yagoub, A. Bellaouar\",\"doi\":\"10.1109/ICSCS.2009.5414149\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, an improved version of the digital calibration method for carrier leakage, which is caused by the DC offset on direct conversion transmitter, is proposed. We have used a power detector for estimating the DC offset. After, we have injected a compensation voltage for eliminating this DC offset. In order to validate our technique, a new direct conversion transmitter that operates at 2GHz, is proposed. The simulation and the implementation of the calibration were performed using the Agilent - ADS software.\",\"PeriodicalId\":300247,\"journal\":{\"name\":\"2009 Mediterrannean Microwave Symposium (MMS)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Mediterrannean Microwave Symposium (MMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSCS.2009.5414149\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Mediterrannean Microwave Symposium (MMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSCS.2009.5414149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
In this paper, an improved version of the digital calibration method for carrier leakage, which is caused by the DC offset on direct conversion transmitter, is proposed. We have used a power detector for estimating the DC offset. After, we have injected a compensation voltage for eliminating this DC offset. In order to validate our technique, a new direct conversion transmitter that operates at 2GHz, is proposed. The simulation and the implementation of the calibration were performed using the Agilent - ADS software.