空气动力发动机系统膨胀比研究

Qihui Yu, M. Cai
{"title":"空气动力发动机系统膨胀比研究","authors":"Qihui Yu, M. Cai","doi":"10.1109/FPM.2011.6045906","DOIUrl":null,"url":null,"abstract":"To increase the energy utilization rate of compressed air, the expansion ration is optimized based on single-staged compressed air power system by building mathematical method with the basic thermodynamic theory. Two-staged compressed air power system mathematical model is built on the basis of research on single-staged compressed air power system. Exergy analysis on air power system is researched on different expansion ratio in 10 MPa pressure and 300K temperature as input condition. Research results indicate two-staged compressed air power system expander is better than single-stage system. Results also show that the first stage expansion ratio is larger impact than the second expansion in two-staged expansion work. The work is foundation for designing valve train system for compressed air powered system","PeriodicalId":241423,"journal":{"name":"Proceedings of 2011 International Conference on Fluid Power and Mechatronics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Research on expansion ratio of air power engine system\",\"authors\":\"Qihui Yu, M. Cai\",\"doi\":\"10.1109/FPM.2011.6045906\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To increase the energy utilization rate of compressed air, the expansion ration is optimized based on single-staged compressed air power system by building mathematical method with the basic thermodynamic theory. Two-staged compressed air power system mathematical model is built on the basis of research on single-staged compressed air power system. Exergy analysis on air power system is researched on different expansion ratio in 10 MPa pressure and 300K temperature as input condition. Research results indicate two-staged compressed air power system expander is better than single-stage system. Results also show that the first stage expansion ratio is larger impact than the second expansion in two-staged expansion work. The work is foundation for designing valve train system for compressed air powered system\",\"PeriodicalId\":241423,\"journal\":{\"name\":\"Proceedings of 2011 International Conference on Fluid Power and Mechatronics\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 2011 International Conference on Fluid Power and Mechatronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FPM.2011.6045906\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 2011 International Conference on Fluid Power and Mechatronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FPM.2011.6045906","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

为提高压缩空气的能量利用率,运用基本热力学理论建立数学方法,对单级压缩空气动力系统的膨胀比进行了优化。在研究单级压缩空气动力系统的基础上,建立了两级压缩空气动力系统的数学模型。研究了在压力为10mpa、温度为300K的输入条件下,不同膨胀比下空气动力系统的火用分析。研究结果表明,两级压缩空气动力系统的膨胀器优于单级系统。结果还表明,在两级膨胀工作中,第一级膨胀比的影响大于第二级膨胀。为压缩空气动力系统配气机构的设计奠定了基础
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on expansion ratio of air power engine system
To increase the energy utilization rate of compressed air, the expansion ration is optimized based on single-staged compressed air power system by building mathematical method with the basic thermodynamic theory. Two-staged compressed air power system mathematical model is built on the basis of research on single-staged compressed air power system. Exergy analysis on air power system is researched on different expansion ratio in 10 MPa pressure and 300K temperature as input condition. Research results indicate two-staged compressed air power system expander is better than single-stage system. Results also show that the first stage expansion ratio is larger impact than the second expansion in two-staged expansion work. The work is foundation for designing valve train system for compressed air powered system
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信