h桥IGBT逆变器死区时间最小化的限制因素研究

Guangye Si, Z. Shen, Zhenbin Zhang, R. Kennel
{"title":"h桥IGBT逆变器死区时间最小化的限制因素研究","authors":"Guangye Si, Z. Shen, Zhenbin Zhang, R. Kennel","doi":"10.1109/SPEC.2016.7845530","DOIUrl":null,"url":null,"abstract":"In order to avoid a bridge shoot-through, a simultaneous on-state of both IGBTs in a bridge leg is strictly forbidden. Therefore, the complementary switch is commonly turned on with a dead-time interval to ensure a complete turn-off the other IGBT. Due to the longer tail-current interval of IGBT switching process, for the purpose of absolute safe operation, the interlocking time to is empirically in microsecond range which normally is much longer than necessary. This raises the questions about whether the tail-current is real a matter of concern, and how can the dead-time be minimized? An IGBT H-bridge inverter with an adjustable interlock time was built in this project, and a series of experiments were carried out to investigate the limiting factors of the dead-time minimization.","PeriodicalId":403316,"journal":{"name":"2016 IEEE 2nd Annual Southern Power Electronics Conference (SPEC)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Investigation of the limiting factors of the dead time minimization in a H-bridge IGBT inverter\",\"authors\":\"Guangye Si, Z. Shen, Zhenbin Zhang, R. Kennel\",\"doi\":\"10.1109/SPEC.2016.7845530\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to avoid a bridge shoot-through, a simultaneous on-state of both IGBTs in a bridge leg is strictly forbidden. Therefore, the complementary switch is commonly turned on with a dead-time interval to ensure a complete turn-off the other IGBT. Due to the longer tail-current interval of IGBT switching process, for the purpose of absolute safe operation, the interlocking time to is empirically in microsecond range which normally is much longer than necessary. This raises the questions about whether the tail-current is real a matter of concern, and how can the dead-time be minimized? An IGBT H-bridge inverter with an adjustable interlock time was built in this project, and a series of experiments were carried out to investigate the limiting factors of the dead-time minimization.\",\"PeriodicalId\":403316,\"journal\":{\"name\":\"2016 IEEE 2nd Annual Southern Power Electronics Conference (SPEC)\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 2nd Annual Southern Power Electronics Conference (SPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPEC.2016.7845530\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 2nd Annual Southern Power Electronics Conference (SPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEC.2016.7845530","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

为了避免桥穿,严格禁止桥腿内两个igbt同时处于导通状态。因此,互补开关通常以死区间隔打开,以确保另一个IGBT完全关断。由于IGBT开关过程的尾电流间隔较长,为了保证绝对安全运行,经验上的联锁时间在微秒范围内,而通常情况下联锁时间要长得多。这就提出了尾电流是否真的是一个值得关注的问题,以及如何将死区时间最小化?本课题设计了一种具有可调联锁时间的IGBT h桥逆变器,并进行了一系列的实验,研究了抑制死区时间最小化的限制因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of the limiting factors of the dead time minimization in a H-bridge IGBT inverter
In order to avoid a bridge shoot-through, a simultaneous on-state of both IGBTs in a bridge leg is strictly forbidden. Therefore, the complementary switch is commonly turned on with a dead-time interval to ensure a complete turn-off the other IGBT. Due to the longer tail-current interval of IGBT switching process, for the purpose of absolute safe operation, the interlocking time to is empirically in microsecond range which normally is much longer than necessary. This raises the questions about whether the tail-current is real a matter of concern, and how can the dead-time be minimized? An IGBT H-bridge inverter with an adjustable interlock time was built in this project, and a series of experiments were carried out to investigate the limiting factors of the dead-time minimization.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信