{"title":"利用喘振抑制电缆抑制电机喘振电压的方法","authors":"K. Narita, Toshihisa Shimizu","doi":"10.1109/ICPE.2015.7167955","DOIUrl":null,"url":null,"abstract":"A novel motor-surge-voltage suppression method using a surge suppression cable that the authors have been developed is presented. The method enables to suppress the motor-surge-voltage which appears on both the motor terminals and the common-mode, and the effectiveness is confirmed by the experiment. Moreover, optimum parameters of the surge suppression cable for more reduction of the each motor surge voltage are discussed through the numerical analysis.","PeriodicalId":160988,"journal":{"name":"2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Suppression method of motor-surge-voltage using the surge suppression cable\",\"authors\":\"K. Narita, Toshihisa Shimizu\",\"doi\":\"10.1109/ICPE.2015.7167955\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel motor-surge-voltage suppression method using a surge suppression cable that the authors have been developed is presented. The method enables to suppress the motor-surge-voltage which appears on both the motor terminals and the common-mode, and the effectiveness is confirmed by the experiment. Moreover, optimum parameters of the surge suppression cable for more reduction of the each motor surge voltage are discussed through the numerical analysis.\",\"PeriodicalId\":160988,\"journal\":{\"name\":\"2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia)\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPE.2015.7167955\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPE.2015.7167955","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Suppression method of motor-surge-voltage using the surge suppression cable
A novel motor-surge-voltage suppression method using a surge suppression cable that the authors have been developed is presented. The method enables to suppress the motor-surge-voltage which appears on both the motor terminals and the common-mode, and the effectiveness is confirmed by the experiment. Moreover, optimum parameters of the surge suppression cable for more reduction of the each motor surge voltage are discussed through the numerical analysis.