具有逆变器接口dg的微电网故障选相方法

P. Praveen, Vishal Kumar
{"title":"具有逆变器接口dg的微电网故障选相方法","authors":"P. Praveen, Vishal Kumar","doi":"10.1109/GlobConHT56829.2023.10087418","DOIUrl":null,"url":null,"abstract":"With the advent of smart protection devices, the utilities have started giving importance to single/double phase tripping for distribution system and microgrid, for which an accurate faulty phase selection is required. Incorporating more inverter-based distributed generation has increased the complexity for the protection devices to select the faulty phases accurately. The inverter-based distributed generations (DGs) show a different fault behavior compared to traditional synchronous-based machines, making the faulty phase selection difficult for the protection devices. This paper briefs the failure of some existing methods to identify the faulty phase and proposes a solution for the problem with a detailed explanation. The effectiveness of the method is tested on a 5-bus system with two photovoltaic distributed generations (DGs)and the results validate that the proposed method successfully selects the faulty phase.","PeriodicalId":355921,"journal":{"name":"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)","volume":"262 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Faulty Phase Selection method for Microgrid with Inverter-Interfaced DGs\",\"authors\":\"P. Praveen, Vishal Kumar\",\"doi\":\"10.1109/GlobConHT56829.2023.10087418\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the advent of smart protection devices, the utilities have started giving importance to single/double phase tripping for distribution system and microgrid, for which an accurate faulty phase selection is required. Incorporating more inverter-based distributed generation has increased the complexity for the protection devices to select the faulty phases accurately. The inverter-based distributed generations (DGs) show a different fault behavior compared to traditional synchronous-based machines, making the faulty phase selection difficult for the protection devices. This paper briefs the failure of some existing methods to identify the faulty phase and proposes a solution for the problem with a detailed explanation. The effectiveness of the method is tested on a 5-bus system with two photovoltaic distributed generations (DGs)and the results validate that the proposed method successfully selects the faulty phase.\",\"PeriodicalId\":355921,\"journal\":{\"name\":\"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)\",\"volume\":\"262 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GlobConHT56829.2023.10087418\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GlobConHT56829.2023.10087418","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

随着智能保护装置的出现,配电系统和微电网的单/双相脱扣问题开始受到重视,这需要准确的故障选相。越来越多的逆变器分布式电源的加入,增加了保护装置准确选择故障相位的复杂性。与传统的同步电机相比,基于逆变器的分布式发电机组表现出不同的故障行为,给保护装置的故障选相带来了困难。本文简要介绍了现有的故障相位识别方法的不足,提出了一种解决方案,并进行了详细的说明。在双光伏分布式发电系统上对该方法的有效性进行了测试,结果表明该方法能够成功地选择故障相位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Faulty Phase Selection method for Microgrid with Inverter-Interfaced DGs
With the advent of smart protection devices, the utilities have started giving importance to single/double phase tripping for distribution system and microgrid, for which an accurate faulty phase selection is required. Incorporating more inverter-based distributed generation has increased the complexity for the protection devices to select the faulty phases accurately. The inverter-based distributed generations (DGs) show a different fault behavior compared to traditional synchronous-based machines, making the faulty phase selection difficult for the protection devices. This paper briefs the failure of some existing methods to identify the faulty phase and proposes a solution for the problem with a detailed explanation. The effectiveness of the method is tested on a 5-bus system with two photovoltaic distributed generations (DGs)and the results validate that the proposed method successfully selects the faulty phase.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信